RANGE
REFRIGERATION – iCORE
Superior cooling capacity at each evaporating temperature.
CO₂ transcritical condensing units - iCO2RE OCU-CR CO₂ Series have a high cooling capacity at each set
point. The CO₂ 2-stage compressor developed by Panasonic is designed to compress CO₂ refrigerant twice;
it reduces the load in operation by half (compared to 1-stage refrigerant compression) and delivers
increased durability and reliability.
Units can be programmed to run at low and medium temperatures at initial set-up. These settings can
then be modified by turning a simple and user-friendly rotary switch to further enhance energy savings.
MT/LT type:
200VF5A ‑ 3,7 / 1,9 kW.
MT type: 400VF8 ‑ 6,9 kW.
MT/LT type: 400VF8A ‑ 7,5 / 3,8 kW.
3,83 SEPR cooling.
1,92 SEPR freezing.
2,45 SEPR cooling.
1,56 SEPR freezing.
*SEPR values has been tested at 3‑part laboratory.
*Model 400VF8A.
OCU-CR200VF5A1).
OCU-CR400VF8 / OCU-CR400VF8A2).
Cooling capacity (kW)
Cooling capacity (kW)
5,0
10,0
4,0
8,0
3,0
6,0
2,0
4,0
1,0
2,0
OCU-CR400VF8A
OCU-CR400VF8
0
–50
–45
–40
–35
–30
–25
–20
–15
–10
–5
0
0
–50
–45
–40
–35
–30
–25
–20
–15
–10
–5
0
–15
–10
–5
0
Evaporation temperature (°C)
Evaporation temperature (°C)
MT type: 1000VF8 ‑ 13,5 kW.
MT/LT type: 1000VF8A ‑ 14,9 / 7,6 kW.
NEW! MT/LT type:
1001VF8A ‑ 16,0 / 8,6 kW.
MT/LT type:
2000VF8A ‑ 28,7 / 14,6 kW.
3,10 SEPR cooling.
1,64 SEPR freezing.
3,00* SEPR cooling.
1,67* SEPR freezing.
*Model 1001VF8A.
OCU-CR1000VF8 / OCU-CR1000VF8A / OCU-CR1001VF8A2).
OCU-CR2000VF8A2).
Cooling capacity (kW)
Cooling capacity (kW)
20,0
35,0
30,0
15,0
25,0
OCU-CR1001VF8A
OCU-CR1000VF8
20,0
10,0
15,0
OCU-CR1000VF8A
10,0
5,0
5,0
0
–50
–45
–40
–35
–30
–25
–20
–15
–10
–5
0
0
–50
–45
–40
–35
Evaporation temperature (°C)
–30
–25
–20
Evaporation temperature (°C)
1) Ambient temperature: 32 °C, 230 V, refrigerant: R744, suction gas temperature: 18 °C. 2) Ambient temperature: 32 °C, 400 V, refrigerant: R744, suction gas temperature:18 °C.
1
Superior efficiency with reliable quality
· Panasonic has combined the 2-stage compressor with the
split cycle for increased efficiency
· High seasonal performance. SEPR: maximum 3,83 in
cooling, 1,92 in freezing*
· High COP at high ambient temperature
*200VF5A.
2
Heat recovery port 1) as renewable energy
3
Flexible installation
· Set-points at medium or low temperature
available depending on applications
· Compact unit
· Silent operation
· Long piping length: maximum 100 m*
· High external static pressure
· Transfer pressure control for stable EEV
expansion valve control in showcases*
*For models 400VF8/A, 1000VF8A, 1001VF8A and 2000VF8A.
· Maximum 16,7 kW of heating for free
· Optional possibility to get subsidy (depending on location)
· Easy connection process
2)
1) For models 1000VF8A, 1001VF8A and 2000VF8A. 2) For model 1000VF8A.