11 REFRIGERATION COVER 26 - Flipbook - Page 25
RANGE
REFRIGERATION – iCORE
NEW
NEW! iCO2RE NCU CO₂ Series · R744
Specifications and capacity tables.
R744
Ultra compact
CO₂ solution
Non-housing compact units for small MT/LT commercial
applications.
Cost-effective solution with natural refrigerant. Indoor and
outdoor installation.
MODEL
NCU-CTC018M05*
NCU-CTC009L05*
Compressor
2-stage compressor
2-stage compressor
Refrigerants
R744
R744
PED category
I
I
Application
MT
LT
230 / PE+N (TN-S)
230 / PE+N (TN-S)
Voltage
Power supply
V
Phase
Frequency
Hz
1
1
50
50
Evaporation temperature
Min ~ Max
°C
-20 ~ 0
-35 ~ -20
Ambient temperature
Min ~ Max
°C
-20 ~ +43
-20 ~ +43
Suction
bar
80
80
Liquid
bar
130
130
mm
750 x 590 x 285
750 x 590 x 285
kg
45
45
Inch (mm)
3/8 (9,52)
3/8 (9,52)
Inch (mm)
1/4 (6,35)
1/4 (6,35)
15
15
PS line
Dimensions
WxHxD
Weight
Suction
Connections
Liquid
Maximum recommended pipe distance
Tentative data
m
*Tentative model name. Panasonic reserves right to change it. Available in Autumn 2026
Cooling capacity at
MT
R744
ET
NCU-CTC018M05
AT
—
—
—
-15 °C
-10 °C
32 °C
Min - Max
kW
—
—
—
1,38
1,78
-5 °C
2,02
38 °C
Min - Max
kW
—
—
—
1,28
1,48
1,78
43 °C
Min - Max
kW
—
—
—
1,20
1,38
1,46
—
Tentative data
Cooling capacity at
LT
R744
ET
NCU-CTC009L05
AT
-35 °C
-30 °C
-25 °C
—
—
32 °C
Min - Max
kW
0,71
0,88
1,04
—
—
—
38 °C
Min - Max
kW
0,65
0,85
0,99
—
—
—
43 °C
Min - Max
kW
0,49
0,78
0,93
—
—
—
Applications: Small cold rooms / cooling equipment.
Cold rooms.
Conventional usage of
condensing units.
EFFICIENT COMPRESSOR
BY PANASONIC
Cooling equipment.
Integrated into cooling
equipment, cabinets, blast
chillers, etc.
AFFORDABLE
CO₂ SOLUTION
MINIMAL
FOOTPRINT
CHECK PAGES 28 - 31 FOR A WIDER SELECTION OF ACCESSORIES
43 °C
CO2
R744
HIGH EFFICIENCY
COMPRESSOR
AMBIENT
TEMPERATURE
25