11 REFRIGERATION COVER 26 - Flipbook - Page 30
GENERAL
Accessories compatibility – iCO2RE CO₂ range
Accessories (can be ordered separately)
SCU-CRC
NCU-CTC009L05
•
•
•
•
•
•
•
•
•
•
Panel-C + MPXPRO, stator, probes, etc +
EEV E2V05CWAC0.
KIT-CO2-PANEL-C-05
•
•
•
•
•
•
•
•
•
•
•
•
Panel-C + MPXPRO, stator, probes, etc +
EEV E2V09CWAC0.
KIT-CO2-PANEL-C-09
•
•
•
•
•
•
•
•
•
•
•
Panel-C + MPXPRO, stator, probes, etc +
EEV E2V11CWAC0.
KIT-CO2-PANEL-C-11
•
•
•
•
•
•
•
•
•
•
•
Panel-C + MPXPRO, stator, probes, etc +
EEV E2V14CWAC0.
KIT-CO2-PANEL-C-14
•
•
•
•
•
•
•
•
•
•
•
Panel-C + MPXPRO, stator, probes, etc +
EEV E2V18CWAC0.
KIT-CO2-PANEL-C-18
•
•
•
•
•
•
•
•
•
•
•
Panel-C + MPXPRO, stator, probes, etc +
EEV E2V24CWAC0.
KIT-CO2-PANEL-C-24
•
•
•
•
•
•
•
•
•
•
•
Panel-C + MPXPRO, stator, probes, etc +
EEV E3V30CWM00.
KIT-CO2-PANEL-C-30
•
•
•
•
•
•
•
•
•
•
•
CZ-CO2-EEV-BOX
•
•
•
•
Room board for EEV control connection kit. CZ-CO2-EEV-KIT
•
•
•
•
Room board for EEV control connection kit,
CZ-CO2-EEV-KIT-03
with sensors and EEV, E2V03CWAC0.
•
•
•
•
Room board for EEV control connection kit,
CZ-CO2-EEV-KIT-05
with sensors and EEV, E2V05CWAC0.
•
•
•
•
Room board for EEV control connection kit,
CZ-CO2-EEV-KIT-09
with sensors and EEV, E2V09CWAC0.
•
•
•
•
Room board for EEV control connection kit,
CZ-CO2-EEV-KIT-11
with sensors and EEV, E2V11CWAC0.
•
•
•
•
Room board for EEV control connection kit,
CZ-CO2-EEV-KIT-14
with sensors and EEV, E2V14CWAC0.
•
•
•
•
Room board for EEV control connection kit,
CZ-CO2-EEV-KIT-18
with sensors and EEV, E2V18CWAC0.
•
•
•
•
Room board for EEV control connection kit,
CZ-CO2-EEV-KIT-24
with sensors and EEV, E2V24CWAC0.
•
•
•
•
Room board for EEV control connection kit,
CZ-CO2-EEV-KIT-30
with sensors and EEV, E3V30CWM00.
•
•
•
•
•
•
•
•
OCU-CRC150A08
•
OCU-CRC060A08
•
OCU-CR1000VF8
•
OCU-CR400VF8A
KIT-CO2-PANEL-C-03
Model
OCU-CR400VF8
Panel-C + MPXPRO, stator, probes, etc +
EEV E2V03CWAC0.
OCU-CR200VF5A
NCU-CTC018M05
NCU
SCU-CRC150A08
OCU-CRC210M08
OCU-CR2000VF8A
OCU-CRC
OCU-CR1001VF8A
OCU-CR
OCU-CR1000VF8A
Series
Compatibility: • Optional accessory / •• Mandatory accessory / ••• One pc. always included as standard with the unit.
Control panels and EEV expansion valves kit
Cold room management via condensing unit interface - Options 1-2-3 + Cold room display
Option 1
Room board for EEV control connection
box.
Option 2
Option 3
Cold room display
Wall-mounted LED display. To be
combined with options 1-2-3.
CZ-CO2-DISPLAY
Oil
CO₂ Lubrication oil PZ-68S (0,5L).
CZ-CO2LBROL500
•
•
•
•
•
•
•
•
•
•
•
•
•
PAW-CO2-PRV60
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Pressure release valves (PRV) for K65
Pressure release valve (PRV) Pset=
60,0 bar (PRV for suction line all units*).
*For OCU-CRC units a suction PRV is available also as
customisation option.
Pressure release valve (PRV) Pset=
80,0 bar (PRV for suction line all units* or
for liquid receiver for OCU-CR400VF8(A),
OCU-CR1000VF8(A), OCU-CR1001VF8A and PAW-CO2-PRV80
OCU-CR2000VF8A).
*For OCU-CRC units a suction PRV is available also as
customisation option.
30
Pressure release valve (PRV)
Pset= 120,0 bar (PRV for liquid receiver for
PAW-CO2-PRV120
OCU-CR200VF5A) and all NCU-CTC models.
•
Changeover valve for dual PRV connection.
•
PAW-CO2-CHANGE-O
•
•
•
•
•
•
•
•
•
•