11 REFRIGERATION COVER 26 - Flipbook - Page 50
GENERAL
iCOOL LCU Series (remote compressor base) · R448A / R449A / R134a / R513A
Specifications and capacity tables.
MODEL
LCU-KRC045M08
LCU-KSC100M08
LCU-KSC160M08
LCU-KSC190M08
Tandem
compressor
Inverter +
ON / OFF
R448A, R449A,
R134a, R513A
Compressor
Single
compressor
Single
compressor
Single
compressor
Tandem
compressor
Inverter +
ON / OFF
Compatible refrigerants
R448A, R449A,
R134a, R513A
R448A, R449A,
R134a, R513A
R448A, R449A,
R134a, R513A
R448A, R449A,
R134a, R513A
PED category
I
II
II
II
II
Application
MT
MT
MT
MT
MT
Cooling capacity at ET -35 °C CT 45 °C
Min ~ Max
kW
—
—
—
—
—
Cooling capacity at ET -10 °C CT 45 °C
Min ~ Max
kW
0,7 - 5,1
1,0 - 7,2
2,3 - 10,0
2,3 - 16,3
2,3 - 19,6
Nominal operating current at ET -10 °C MT / -30 °C LT AT 32 °C
and 400 V 50 Hz
A
4,9
7,5
12,1
19,5
24,5
Maximum operating current (in the most loaded phase at 400 V
50 Hz)
A
7,5
11,4
17,9
25,9
30,3
Maximum power consumption
kW
3,5
5,4
8,4
13,6
16,7
Dimensions
mm
1 000 x 705 x 530
1 000 x 772 x 507
1 200 x 775 x 561
1 300 x 874 x 662
1 300 x 874 x 662
WxHxD
Weight
kg
85
89
124
209
211
Sound level at 10 m
dB(A)
39,0
42,0
54,0
54,0
54,0
Sound level at 10 m with housing “H” customisation option
dB(A)
36,0
39,0
51,0
51,0
51,0
C-7RVN113L0A
C-7RZ320L4ABL
C-SBS180H00B
C-SBS180H00B/
C-SBN303H8G
C-SBS180H00B/
C-SBN453H8G
5,8 - 17,4 / 14,7
Model
Volumetric flow
m³/h
1,25 - 7,5
1,7 - 10,4
5,8 - 17,4
5,8 - 17,4 / 11,6
Rotation range
rps
15-90
15-90
32-90
32-90
32-90
A
5,8
8,7
14,7
14,7 / 8,0
15,2 / 11,9
11,2 / —
15 / —
34 / —
34 / 48
34 / 66
FV68S (PVE)
Compressor
Full load amperage
Current
Peak current limit / Locked rotor
A
amperage
Oil type
FV68S (PVE)
FV68S (PVE)
FV68S (PVE)
FV68S (PVE)
W
35
40
70
2x70
2x70
dm³
0,7 + 0,4
0,7 + 0,4
2,0 + 0,4
2,0 + 1,7 + 2x0,4
2,0 + 1,7 + 2x0,4
Suction
Inch
5/8
3/4
7/8
1 1/8
1 1/8
Liquid
Inch
3/8
3/8
1/2
5/8
5/8
dm³
3,9
7,1
10,0
14
14
Voltage
V / Hz
3x400 / 50 PE+N
(TN-S)
3x400 / 50 PE+N
(TN-S)
3x400 / 50 PE+N
(TN-S)
3x400 / 50 PE+N
(TN-S)
3x400 / 50 PE+N
(TN-S)
Recommended minimum cable cross-section
mm²
5x2,5
5x2,5
5x4,0
5x6,0
5x10,0
C16
C16
C25
C32
C40
m
40
40
40
50
50
Evaporator above
m
12
12
12
12
12
Evaporator below
m
12
12
12
12
12
Suction
Suction
Suction
Suction
Suction
13
Crankcase heater power consumption
Oil charge
Connections
Liquid receiver
CU power
supply
Recommended minimum protection
Maximum recommended pipe distance
Maximum height distance
Which pipes needs to be insulated
Suction / liquid / both
Recommended insulation thickness
mm
13
13
13
13
Maximum quantity of evaporators connected
Qty.
5
5
7
10
10
Evaporation temperature
Min ~ Max
°C
-15 ~ 5
-15 ~ 5
-15 ~ 10
-15 ~ 10
-15 ~ 10
Ambient temperature
Min ~ Max
°C
-20 ~ 43
-20 ~ 43
-20 ~ 43
-20 ~ 43
-20 ~ 43
CHECK PAGE 57 FOR A SELECTION OF ACCESSORIES
HIGH EFFICIENCY
COMPRESSOR
50
LCU-KRC070M08
BMS
CONNECTIVITY