Hydronics Brochure - FINAL - Flipbook - Page 20
GENERAL INDEX
Air cooled chillers, heat pumps and condensing units
ECOi‑W VL H/E · R410A
4 scroll compressors.
Plate heat exchanger.
Operation range: OAT ‑5 to 47 °C in cooling and ‑10 to 20 °C in heating (STD units).
LWT ‑8 (with Brine option) to 15 °C in cooling and 30 to 50 °C in heating.
Outdoor unit
Cooling
capacity 1)
STD ‑ HPF / L
/ S / HT
ErP data 2)
SEER
ηs,c
STD ‑ HPF
/ L / S / HT
STD ‑ HPF
/ L / S / HT
kW
Heating
capacity 3)
STD ‑ HPF / L
/ S / HT
ErP data 2) 4)
Sound power 5) Dimension
SCOP
ηs,h
STD ‑ HPF
/ L / S / HT
STD ‑ HPF
/ L / S / HT
kW
Operating weight
HxWxL
STD ‑ HPF / L
/ S / HT
STD ‑ HPF ‑ L /
S / HT
dB(A)
mm
kg
ECOi‑W VL 704‑1 204 H ‑ heat pump
704
P‑VLE0704HA
173,2 / 168,2 /
164,3 / 175,6
3,63 / 3 /
3,63 / 3
142 / 117 /
142 / 117
200,1 / 195,0 /
184,9 / 200,7
3,41 / 3,41 / 133 / 133 /
3,41 / 3,44
133 / 135
93 / 87 / 83 / 99
2 300 x 1 100 x 4 300
1 675 / 1 710 /
1 705
804
P‑VLE0804HA
197,1 / 191,2 /
185,2 / 199,7
3,55 / 3 /
3,55 / 3
139 / 117 /
139 / 117
223,2 / 217,1 /
202,9 / 224,0
3,42 / 3,42 / 134 / 134 /
3,42 / 3,40
134 / 133
93 / 87 / 83 / 99
2 300 x 1 100 x 4 300
1 820 / 1 855 /
1 850
904
P‑VLE0904HA
226,4 / 220,4 /
214,5 / 229,5
3,35 / 3,1 /
3,35 / 3,1
131 / 121 /
131 / 121
254,7 / 247,7 /
232,6 / 256,6
3,28 / 3,28 / 128 / 128 /
3,28 / 3,32
128 / 130
94 / 88 / 84 / 100 2 300 x 1 100 x 4 300
1 980 / 2 015 /
2 020
1 004
P‑VLE1004HA
246,3 / 237,3 /
230,4 / 250,1
3,5 / 3,28 /
3,5 / 3,28
137 / 128 /
137 / 128
270,8 / 261,8 /
245,7 / 273,7
3,39 / 3,39 / 133 / 133 /
3,39 / 3,33
133 / 130
94 / 88 / 84 / 100 2 300 x 1 100 x 4 300
2 125 / 2 165 /
2 165
1 104
P‑VLE1104HA
273,1 / 261,2 /
253,3 / 276,5
3,53 / 3,3 /
3,53 / 3,3
138 / 129 /
138 / 129
302,1 / 288,9 /
266,8 / 305,5
3,30 / 3,20 / 129 / 125 /
3,30 / 3,37
129 / 132
95 / 89 / 85 / 100 2 300 x 1 100 x 4 300
2 215 / 2 255 /
2 255
1 204
P‑VLE1204HA
299,9 / 285,1 /
276,1 / 305,6
3,43 / 3,23 / 134 / 126 /
3,43 / 3,23
134 / 126
337,4 / 322,2 /
297,0 / 341,5
3,19 / 3,19 / 125 / 125 /
3,19 / 3,26
125 / 127
95 / 89 / 85 / 100 2 300 x 1 100 x 4 300
2 225 / 2 265 /
2 265
ECOi‑W VL 704‑1 204 E ‑ condensing unit
704
P‑VLE0704EA
199,0 / 194,0 /
188,5 / 201,0
—
—
—
—
—
93 / 87 / 83 / 99
2 300 x 1 100 x 4 300
1 490 / 1 525 /
1 520
804
P‑VLE0804EA
224,0 / 218,0 /
211,0 / 226,5
—
—
—
—
—
93 / 87 / 83 / 99
2 300 x 1 100 x 4 300
1 615 / 1 650 /
1 645
904
P‑VLE0904EA
258,0 / 251,0 /
244,0 / 261,0
—
—
—
—
—
94 / 88 / 84 / 100 2 300 x 1 100 x 4 300
1 700 / 1 735 /
1 740
1 004
P‑VLE1004EA
283,0 / 272,5 /
264,5 / 286,5
—
—
—
—
—
94 / 88 / 84 / 100 2 300 x 1 100 x 4 300
1 825 / 1 865 /
1 865
1 104
P‑VLE1104EA
315,0 / 301,0 /
292,0 / 318,0
—
—
—
—
—
95 / 89 / 85 / 100 2 300 x 1 100 x 4 300
1 910 / 1 950 /
1 950
1 204
P‑VLE1204EA
347,0 / 330,0 /
319,0 / 353,0
—
—
—
—
—
95 / 89 / 85 / 100 2 300 x 1 100 x 4 300
1 920 / 1 960 /
1960
Water connections information. ECOi‑W VL 704‑1 204 H STD / HPF ‑ heat pump
Outdoor unit
704
Type of water connections (evaporator)
Male gas threaded Male gas threaded Male gas threaded Male gas threaded Male gas threaded Male gas threaded
Water inlet/outlet diameter
Inch
2½
804
2½
904
1 004
1 104
1 204
3
3
3
3
Refrigerant connections information. ECOi‑W VL 704‑1 204 E ‑ condensing unit
Inlet diameter
Outlet diameter
Inch
⅞
⅞
1⅛
1⅛
1⅛
1⅛
Inch
1⅝
1⅝
2⅛
2⅛
2⅛
2⅛
1) According EN 14511-2013: chilled water inlet/outlet temperature: 12/7 °C, outdoor ambient temperature 35 °C DB. For condensing unit models: Data refers to 7 °C leaving chilled water temperature and
35 °C condenser air temperature. 2) According EN 14825. 3) According EN 14511-2013: warm water inlet/outlet temperature: 40/45 °C, outdoor ambient temperature 7 °C DB/6 °C WB. 4) ErP compliant:
following COMMISSION REGULATION (EU) No 813/2013. 5) Sound levels are at fully loaded conditions. Sound power values refers to ISO 3744 standard.
* Check data and configuration on AC SELECT. POA: Price On Applications.
20
Accessories and options
Accessories and options
Anti‑vibration spring dampers
Mechanical gauges
Automatic circuit breaker
Overload protection for compressors
Coils treatments
Power factor corrector capacitors
Compressor jackets (standard on S)
Several communication protocols
Desuperheater
Soft starter
Fan speed control (‑18 °C)
Unit protection grilles
Hydrokit with 1 or 2 pumps with or without buffer tank (500 L) (+1 m of length)
Water filter
Inverter fans
Water flow switch