Hydronics Brochure - FINAL - Flipbook - Page 21
CHILLERS AND HEAT PUMPS
HYDRONICS INDEX
Air cooled chillers, heat pumps and condensing units
ECOi‑W AQUA EVO 230‑360 C/H/E · R410A
4 scroll compressors.
Plate heat exchanger.
Operation range: OAT 5 to 48 °C in cooling and ‑10 to 20 °C in heating (STD units).
LWT ‑10 (with Brine option) to 18 °C in cooling and 20 to 55 °C in heating.
Outdoor unit
ErP data 2) 3)
Nominal heating
capacity 4) 5)
Nominal
cooling
capacity 1)
SEER
ηs,C
STD / L /
S / HT
STD / L /
S / HT
STD / L /
S / HT
kW
40‑45 °C
30‑35 °C
STD / L /
S / HT
STD / L /
S / HT
ErP data 3) 6)
SCOP
ηs,h
Sound
power 7)
STD / L /
S / HT
STD / L /
S / HT
STD / L /
S / HT
kW
Dimension
Operating weight 8)
HxWxL
STD / L /
S / HT
dB(A)
mm
kg
ECOi‑W AQUA EVO 230‑360 C ‑ chiller
230
P‑AQAVE0230CA
231 / 224 /
210 / 232
4,25 / 4,28 /
4,1 / 4,63
167 / 168 /
161 / 182
—
—
—
—
92 / 87 /
82 / 94
2 500 x 2 150 x 3 500
1 693 / 1 693 /
1 698 / 1 743
260
P‑AQAVE0260CA
263 / 256 /
242 / 265
4,25 / 4,28 /
4,15 / 4,65
167 / 168 /
163 / 183
—
—
—
—
93 / 88 /
83 / 96
2 500 x 2 150 x 3 500
1 890 / 1 890 /
1 895 / 1 950
280
P‑AQAVE0280CA
284 / 276 /
259 / 286
4,23 / 4,25 /
4,1 / 4,63
166 / 167 /
161 / 182
—
—
—
—
93 / 88 /
83 / 96
2 500 x 2 150 x 3 500
1 953 / 1 953 /
1 958 / 2 013
300
P‑AQAVE0300CA
310 / 301 /
283 / 312
4,18 / 4,25 /
4,1 / 4,68
164 / 167 /
161 / 184
—
—
—
—
94 / 89 /
85 / 97
2 500 x 2 150 x 4 550
2 227 / 2 227 /
2 232 / 2 297
330
P‑AQAVE0330CA
331 / 322 /
305 / 333
4,20 / 4,25 /
4,1 / 4,65
165 / 167 /
161 / 183
—
—
—
—
95 / 90 /
86 / 98
2 500 x 2 150 x 4 550
2 345 / 2 345 /
2 350 / 2 425
360
P‑AQAVE0360CA
362 / 351 /
329 / 364
4,10 / 4,10 /
4,1 / 4,43
161 / 161 /
161 / 174
—
—
—
—
95 / 90 /
86 / 98
2 500 x 2 150 x 4 550
2 519 / 2 519 /
2 524 / 2 599
ECOi‑W AQUA EVO 230‑360 H ‑ heat pump
230
P‑AQAVE0230HA
214 / 207 /
194 / 216
4,13 / 4,13 /
4,13 / 3,8
162 / 162 /
162 / 149
229 / 224 /
220 / 232
234 / 228 /
223 / —
3,46 / 3,46 /
3,46 / 3,56
135 / 135 /
135 / 139
92 / 87 /
82 / 94
2 500 x 2 150 x 3 500
2 078 / 2 078 /
2 083 / 2 128
260
P‑AQAVE0260HA
244 / 237 /
224 / 246
4,05 / 4,05 /
4,05 / 3,73
159 / 159 /
159 / 146
262 / 256 /
251 / 266
269 / 261 /
255 / —
3,48 / 3,48 /
3,48 / 3,57
136 / 136 /
136 / 140
93 / 88 /
83 / 96
2 500 x 2 150 x 3 500
2 343 / 2 343 /
2 348 / 2 403
280
P‑AQAVE0280HA
261 / 253 /
239 / 263
4,1 / 4,1 /
3,60 / 3,78
161 / 161 /
141 / 148
280 / 272 /
267 / 284
286 / 277 /
271 / —
3,44 / 3,44 /
3,44 / 3,53
135 / 135 /
135 / 138
93 / 88 /
83 / 96
2 500 x 2 150 x 3 500
2 458 / 2 458 /
2 463 / 2 518
300
P‑AQAVE0300HA
288 / 279 /
263 / 290
3,83 / 3,83 /
3,83 / 4,28
150 / 150 /
150 / 168
306 / 299 /
295 / 310
311 / 304 /
298 / —
3,51 / 3,51 /
3,51 / 3,61
137 / 137 /
137 / 141
94 / 89 /
85 / 97
2 500 x 2 150 x 4 550
2 702 / 2 702 /
2 707 / 2 772
330
P‑AQAVE0330HA
307 / 299 /
284 / 310
3,8 / 3,8 /
3,8 / 3,95
149 / 149 /
149 / 155
327 / 321 /
315 / 332
334 / 326 /
320 / —
3,44 / 3,44 /
3,44 / 3,55
135 / 135 /
135 / 139
95 / 90 /
86 / 98
2 500 x 2 150 x 4 550
2 887 / 2 887 /
2 892 / 2 967
360
P‑AQAVE0360HA
341 / 330 /
311 / 343
3,93 / 3,93 /
3,93 / 4,08
154 / 154 /
154 / 160
361 / 354 /
349 / 367
368 / 359 /
353 / —
3,48 / 3,48 /
3,48 / 3,58
136 / 136 /
136 / 140
95 / 90 /
86 / 98
2 500 x 2 150 x 4 550
3 063 / 3 063 /
3 068 / 3 143
ECOi‑W AQUA EVO 230‑360 E ‑ condensing unit
230
P‑AQAVE0230EA
250 / 242 /
225 / 253
—
—
—
—
—
—
92 / 87 /
82 / 94
2 500 x 2 150 x 3 500
1 542
260
P‑AQAVE0260EA
288 / 279 /
262 / 291
—
—
—
—
—
—
93 / 88 /
83 / 96
2 500 x 2 150 x 3 500
1 726
280
P‑AQAVE0280EA
313 / 302 /
281 / 316
—
—
—
—
—
—
93 / 88 /
83 / 96
2 500 x 2 150 x 3 500
1 788
300
P‑AQAVE0300EA
337 / 326 /
305 / 341
—
—
—
—
—
—
94 / 89 /
85 / 97
2 500 x 2 150 x 4 550
1 946
330
P‑AQAVE0330EA
361 / 351 /
330 / 364
—
—
—
—
—
—
95 / 90 /
86 / 98
2 500 x 2 150 x 4 550
2 061
360
P‑AQAVE0360EA
395 / 381 /
356 / 398
—
—
—
—
—
—
95 / 90 /
86 / 98
2 500 x 2 150 x 4 550
2 235
Water connections. ECOi‑W AQUA EVO 230‑360 C/H ‑ chiller / heat pump
Outdoor unit
230
Type of water connections (evaporator)
Male gas threaded Male gas threaded Male gas threaded Male gas threaded Male gas threaded Male gas threaded
Water inlet/outlet diameter
Inch
260
3
3
280
3
300
330
3
3
360
3
Refrigerant connections information. ECOi‑W AQUA EVO 230‑360 E ‑ condensing unit
Type of refrigerant connections
To be brazed
To be brazed
To be brazed
To be brazed
To be brazed
To be brazed
Inlet diameter
Inch
1⅝ ‑ 2⅛
1⅝ ‑ 2⅛
1⅝ ‑ 2⅛
2⅛
2⅛
2⅛
Outlet diameter
Inch
⅞ ‑ 1⅛
⅞ ‑ 1⅛
⅞ ‑ 1⅛
1⅛
1⅛
1⅛
1) According EN 14511-2013: chilled water inlet/outlet temperature: 12/7 °C, outdoor ambient temperature 35 °C DB. For condensing unit models: Data refers to 7 °C leaving chilled water temperature and
35 °C condenser air temperature. 2) ErP compliant: following COMMISSION REGULATION (EU) 2016/2281. 3) According EN 14825. 4) According EN 14511-2013: warm water inlet/outlet temperature: 40/45 °C,
outdoor ambient temperature 7 °C DB/6 °C WB. 5) According EN 14511-2013: warm water inlet/outlet temperature: 30/35 °C, outdoor ambient temperature 7 °C DB/6 °C WB. 6) ErP compliant: following
COMMISSION REGULATION (EU) No 813/2013. 7) Sound levels are at fully loaded conditions. Sound power values refers to ISO 3744 standard. 8) Shipping weight for condensing unit models.
* Check data and configuration on AC SELECT. POA: Price On Applications.
Accessories and options
Accessories and options
Accessories and options
Anti‑vibration spring dampers
Soft starter
Automatic circuit breaker
Hydrokit with 1 or 2 pumps with or without buffer
tank (500 L)
Coils treatments
Mechanical gauges
Variable pump
Desuperheater
Overload protection for compressors
Water filter
Fan speed control (‑14 °C in cooling mode –
standard as super low noise version)
Power factor corrector capacitors
Water flow switch
Unit protection grilles
Several communication protocols
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
21