Air cooled chillers, heat pumps and condensing units
ECOi‑W SW‑N EVO 380‑1 260 C · R513A
Hybrid screw compressors combination: Inverter + step control.
Shell and tubes evaporator.
Operation range: OAT ‑10 (with Brine option) to 46 °C in cooling (STD units).
LWT 5 to 15 °C in cooling.
Outdoor unit
Nominal cooling
capacity 1)
ErP data 2) 3)
SEER
ηs,c
STD ‑ HT ‑ HP / S
STD ‑ HT ‑ HP / S
STD ‑ HT ‑ HP / S
Sound power 4)
kW
Dimension
Operating weight
Height
WxL
STD ‑ HT ‑ HP / S
STD ‑ HT ‑ HP / S
dB(A)
mm
mm
STD ‑ HT ‑ HP / S
kg
ECOi‑W SW‑N EVO 380‑1 260 C ‑ chiller
380
P‑SWVN0380CA
365,7 / 362,8
4,53 / 4,56
178 / 180
97 / 94
2 510 / 2 590
2 192 x 4 660
3 896 / 3 981
440
P‑SWVN0440CA
443,0 / 441,8
4,64 / 4,82
182 / 190
98 / 94
2 510 / 2 590
2 192 x 5 712
4 259 / 4 352
510
P‑SWVN0510CA
500,2 / 498,2
4,65 / 4,79
183 / 189
100 / 97
2 510 / 2 590
2 192 x 5 712
4 897 / 4 990
590
P‑SWVN0590CA
565,8 / 563,1
4,80 / 4,89
189 / 193
100 / 97
2 510 / 2 590
2 192 x 6 764
5 241 / 5 323
660
P‑SWVN0660CA
643,5 / 640,0
4,66 / 4,78
183 / 188
100 / 97
2 510 / 2 590
2 192 x 7 816
5 620 / 5 702
730
P‑SWVN0730CA
704,3 / 702,5
4,56 / 4,73
179 / 186
101 / 98
2 510 / 2 590
2 192 x 7 816
6 207 / 6 293
810
P‑SWVN0810CA
778,1 / 775,9
4,62 / 4,77
182 / 188
101 / 98
2 510 / 2 590
2 192 x 8 868
6 531 / 6 617
900
P‑SWVN0900CA
896,9 / 893,1
4,56 / 4,69
179 / 185
102 / 99
2 510 / 2 590
2 192 x 9 920
7 326 / 7 412
980
P‑SWVN0980CA
983,5 / 980,9
4,60 / 4,82
181 / 190
102 / 99
2 510 / 2 590
2 192 x 10 972
7 764 / 7 852
1 060
P‑SWVN1060CA
1047,4 / 1045,5
4,87 / 4,98
192 / 196
103 / 99
2 510 / 2 590
2 192 x 12024
8 491 / 8 579
1 160
P‑SWVN1160CA
1154,0 / 1150,6
4,86 / 5,07
191 / 200
103 / 100
2 510 / 2 590
2 192 x 13 076
8 875 / 8 963
1 260
P‑SWVN1260CA
1240,5 / 1234,8
4,85 / 5,03
191 / 198
103 / 100
2 510 / 2 590
2 192 x 13 076
9 074 / 9 162
1) Data refers to 7 °C leaving chilled water temperature and 35 °C condenser air temperature, according EN 14511-2013 standard. 2) ErP compliant: following COMMISSION REGULATION (EU) 2016/2281.
3) According EN 14825. 4) Sound levels are at fully loaded conditions. Sound power values refer to ISO standard 3744.
* High temperature units (HT), data with fans at maximum speed (1 100 r.p.m.). ** HPF units, data with fans at maximum speed (1 100 r.p.m.).
* Check data and configuration on AC SELECT. POA: Price On Applications.
Accessories and options
Accessories and options
Antifreeze electric heater for hydraulic manifolds
Flow switch
Anti‑vibration spring dampers
Hydro kit 1P‑SP/1P‑HP/2P‑SP/2PHP
Chiller grilles
Mechanical gauges kit (HP and LP manometers)
Compressor acoustic box
Power factor corrector capacitors
Compressor star delta start
Several communication protocols
Compressor suction valve
Variable pump
E‑coating treatment
Water filter
Finned tubes (Al/Cu)
Technological innovation.
All-round variable volume flow management.
Refrigerant.
Inverter driven compressor technology and
electronic expansion valve.
Air.
EC brushless fan motor technology.
Water.
Inverter driven pump technology.
Improved part load efficiency.
Continuous capacity control.
Flexible offer in plant integration.
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
23