Hydronics Brochure - FINAL - Flipbook - Page 41
FAN COIL
CHILLERS
UNITS
FAN COIL UNITS INDEX
Fan coil units
Fan coil wall AC fan
Version: 2‑pipes.
3‑speed AC fan motor.
Version with infrared remote controller (IR).
Fan coils
Air flow
Dimension
Cooling 1)
Total capacity (Hi)
Heating 2)
Max
HxWxD
kW
kW
m³/h
mm
Weight
kg
2‑pipes, without valve
1ph
P‑FW07
P‑FW07IR (included IR controller)
1,69
1,72
360
275 x 845 x 180
11
P‑FW09
P‑FW09IR (included IR controller)
2,50
2,80
551
275 x 845 x 180
11
P‑FW18
P‑FW18IR (included IR controller)
3,60
4,10
680
298 x 940 x 200
13
P‑FW22
P‑FW22IR (included IR controller)
4,00
4,50
850
298 x 940 x 200
13
2‑pipes, with 3W valve included IR controller
1ph
P‑FW09IR‑3W
1,40
2,00
400
275 x 845 x 180
11
P‑FW22IR‑3W
3,10
3,30
600
298 x 940 x 200
13
Water connections information
2‑pipes, without valve
Fan coils
07
09
18
22
09
22
Type of connections
Female gas threaded
Female gas threaded
Female gas threaded
Female gas threaded
Female gas threaded
Female gas threaded
½
½
½
½
½
½
Water connections
Inch
2‑pipes, with valve
1) According to Eurovent standard. Air: 27 °C DB/19 °C WB, chilled water: 7 °C/12 °C. 2) According to Eurovent standard. Air: 20 °C, hot water: 45 °C/40 °C.
* These prices don’t include accessories and options. ** Check data and configuration on AC SELECT. *** Check units availability.
Accessories and options
Accessories and options
Accessories and options
2 way or 3 way valves
Modbus communication board for Plogic
Plogic controller (other electromechanical
or electronic control systems also available)
SRC ‑ mini BMS controller
WRC: wall‑mounted remote control for Plogic
TControl EASY 3S and TControl POD glass
controllers (other electromechanical or
electronic control systems also available)
Fan coil duct EC fan
Versions: 2‑pipes, 2‑pipes + electric heater and 4‑pipes.
Low energy consumption EC fan.
Fan coils
2‑pipe
1ph
4‑pipe
Total capacity
Energy efficiency class 3)
Cooling 1)
Heating 2)
FCEER
FCCOP
A to E
A to E
Hi
Hi
kW
kW
P‑FD10
1,50
1,82
C
P‑FD15
2,06
2,55
P‑FD20
2,74
P‑FD25
Air flow 4)
External static Dimension
pressure
Without drain pan ‑ horizontal installation
Max
Weight
HxWxD
m³/h
Pa
mm
kg
C
357
62,6
223 x 633 x 631
14
B
A
491
82
223 x 733 x 631
16
2,59
B
B
599
72
223 x 833 x 631
18
3,20
3,39
B
A
642
70
223 x 933 x 631
20
P‑FD30
4,80
5,01
B
B
1 068
105
223 x 933 x 631
22
P‑FD40
6,66
7,06
A
A
1 293
116
223 x 1 233 x 653
29
P‑FD10
1,58
2,16
C
C
384
51,8
223 x 633 x 631
14
P‑FD15
2,18
2,88
B
A
452
83
223 x 733 x 631
16
P‑FD20
2,74
3,12
B
A
560
72
223 x 833 x 631
18
P‑FD25
2,94
4,03
B
A
602
72
223 x 933 x 631
20
P‑FD30
4,57
4,10
B
B
943
104
223 x 933 x 631
22
P‑FD40
6,37
6,61
A
A
1 228
117
223 x 1 233 x 653
29
Water connections information
Fan coils
10
Type of connections
Female gas threaded Female gas threaded Female gas threaded Female gas threaded Female gas threaded Female gas threaded
15
20
25
30
40
Water connections 2 or 4‑pipes (cooling)
Inch
½
½
½
½
½
¾
Water connections 4‑pipes (heating)
Inch
½
½
½
½
½
½
1) According to Eurovent standard. Air: 27 °C DB/19 °C WB, chilled water: 7 °C/12 °C. 2) According to Eurovent standard. Air: 20 °C, hot water: 45 °C/40 °C. For 4-pipes models: According to Eurovent standard.
Air: 20 °C, hot water: 65 °C/55 °C. 3) According to Eurovent. 4) According to Eurovent 6/10 (air flow test method) and 8/12 (sound test method).
* Data with I configuration with rectangular return and discharge and G2 (P-FD10/15/20/25/30) or G3 (P-FD40) filter.
* These prices don’t include accessories and options. ** Check data and configuration on AC SELECT.
Accessories and options
Accessories and options
Accessories and options
2 way or 3 way valves
Many air inlet/outlet configurations
Circuit breakers
Condensate drain pump
Electromechanical sensor for automatic
change over
Plogic controller (other electromechanical
or electronic control systems also
available)
Ecospeed card for EC fans
Modbus communication board for Plogic
Electric heaters (from 500 W to 2 500 W)
Fresh air intake
Other speeds configuration (standard factory
set speeds in technical features table)
Fuse holder
SRC ‑ mini BMS controller
G2/G3 filter
Suspension kit
TControl EASY 3S and TControl POD glass
controllers (other electromechanical or
electronic control systems also available)
WRC: wall‑mounted remote control for
Plogic
41