GENERAL INDEX
Fan coil units
Fan coil high static duct AC/EC fan
Versions: 2‑pipes, 2‑pipes + electric heater and 4‑pipes.
5 or 4‑speed AC fan or low energy consumption EC fan.
Fan coils
Energy efficiency class 3)
External static
pressure
Dimension
m³/h
Pa
mm
kg
C
1 125
70
250 x 1 200 x 698
42
C
2 830
90
375 x 1 380 x 798
63
D
C
2 830
90
375 x 1 380 x 798
65
17,80
D
C
2 830
90
375 x 1 380 x 798
67
19,03
20,90
D
D
3 736
75
450 x 1 500 x 798
76
P‑FH27
21,90
21,50
D
D
3 736
75
450 x 1 500 x 798
80
P‑FH7
5,08
7,70
D
C
974
70
250 x 1 200 x 698
42
P‑FH15
11,33
21,00
D
C
2 830
90
375 x 1 380 x 798
63
P‑FH18
12,83
21,00
D
C
2 830
90
375 x 1 380 x 798
65
P‑FH21
17,43
21,00
D
C
2 830
90
375 x 1 380 x 798
67
P‑FH24
17,13
15,20
D
D
3 736
75
450 x 1 500 x 798
76
P‑FH27
19,13
29,60
D
D
3 736
75
450 x 1 500 x 798
80
P‑FH7
5,88
9,26
—
—
1 293
116
250 x 1 200 x 698
42
P‑FH15
11,10
13,00
A
A
2 335
65
375 x 1 380 x 798
63
P‑FH18
12,80
14,60
A
A
2 335
65
375 x 1 380 x 798
65
P‑FH21
13,90
15,80
A
A
2 335
65
375 x 1 380 x 798
67
P‑FH24
17,60
19,50
B
A
3 098
66
450 x 1 500 x 798
76
P‑FH27
19,90
21,40
A
A
3 098
66
450 x 1 500 x 798
80
P‑FH7
5,54
9,05
—
—
1 229
117
250 x 1 200 x 698
42
P‑FH15
8,91
8,13
B
B
2 335
65
375 x 1 380 x 798
63
P‑FH18
10,00
14,20
B
A
2 335
65
375 x 1 380 x 798
65
P‑FH21
12,40
14,20
A
A
2 335
65
375 x 1 380 x 798
67
P‑FH24
15,20
13,00
A
B
3 098
66
450 x 1 500 x 798
76
P‑FH27
16,80
12,90
A
B
3 098
66
450 x 1 500 x 798
80
Total capacity
FCEER
FCCOP
kW
A to E
A to E
5,59
6,70
D
13,33
15,48
D
P‑FH18
13,87
18,01
P‑FH21
17,00
P‑FH24
Cooling 1)
Heating 2)
Hi
Hi
kW
P‑FH7
P‑FH15
Air flow 4)
Max
Weight
Horizontal installation
HxWxD
Fan coil high static duct AC fan
2‑pipe
1ph
4‑pipe
Fan coil high static duct EC fan
2‑pipe
1ph
4‑pipe
Water connections information
Fan coils
07
15
Type of connections
Female gas
threaded
18
21
24
27
Male gas threaded Male gas threaded Male gas threaded Male gas threaded Male gas threaded
Water connections 2‑pipe
Inch
½
1
1¼
1¼
1¼
1¼
Water connections 4‑pipe (cooling ‑ heating)
Inch
½‑½
1‑¾
1‑¾
1‑¾
1¼ ‑ ¾
1¼ ‑ ¾
1) According to Eurovent standard. Air: 27 °C DB/19 °C WB, chilled water: 7 °C/12 °C. 2) According to Eurovent standard. Air: 20 °C, hot water: 45 °C/40 °C. For 4-pipes models: According to Eurovent standard.
Air: 20 °C, hot water: 65 °C/55 °C. 3) According to Eurovent. 4) According to Eurovent 6/10 (air flow test method) and 8/12 (sound test method).
* Data with I configuration with rectangular return and discharge.
* These prices don’t include accessories and options. ** Check data and configuration on AC SELECT.
Accessories and options
Accessories and options
2 way or 3 way valves
Modbus communication board for Plogic
Auxiliary drain pan
Other speeds configuration (standard factory set speeds in technical features table)
Circuit breakers
Condensate drain pump
SRC ‑ mini BMS controller
Double skin acoustic insulation
Suspension kit
Electric heaters (from 1 000 W to 3 000 W)
Plogic controller (other electromechanical or electronic control systems also
available)
Fresh air intake
Fuse holder
G3/G4 filter
TControl EASY 3S and TControl POD glass controllers (other electromechanical or
electronic control systems also available)
Inlet and outlet plenums for circular ducts (07 only)
WRC: wall‑mounted remote control for Plogic
Electromechanical sensor for automatic change over
42
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.