IRE A2W Price List FINAL - Flipbook - Page 17
AQUAREA
AQUAREA INDEX
Aquarea High Performance Hydraulic
NEW Aquarea High Performance Hydraulic M Series Single
phase · R290
R290
Water outlet temperature up to 75 °C down to -15 °C. Wi-Fi
adapter included for smart control via Panasonic Comfort Cloud
App. Operation range down to -25 °C in heating.
New 2025
Included
Outdoor unit
Combination table
Heating capacity
DHW tank
Backup
heater
capacity
120 L
3 kW
120 L
3 kW
Single phase
Electrical
anode
Indoor unit
1ph
Hydraulic All in One
3ph
1ph
Hydraulic Bi-bloc
3ph
Control module
Remote controller with Wi-Fi adapter
12,0 kW
16 kW
WH-WDG12ME5
WH-WDG16ME5
7,869
RRP €
6,913
WH-ADC0916M3E51
4,911
✔
✔
✔
WH-ADC0916M3E5AN1
5,295
✔
✔
WH-ADC0916M3E52
5,017
✔
✔
✔
WH-ADC0916M3E5AN2
5,240
✔
✔
✔
185 L
3 kW
185 L
3 kW
185 L
6 kW
WH-ADC0916M6E52
5,403
✔
260 L
3 kW
WH-ADC0916M3E53
5,305
✔
✔
260 L
3 kW
WH-ADC0916M3E5AN3
6,004
✔
✔
260 L
6 kW
WH-ADC0916M6E53
5,944
✔
✔
185 L
9 kW
WH-ADC0316M9E82
5,467
✔
✔
185 L
9 kW
WH-ADC0316M9E8AN2
6,579
✔
✔
260 L
9 kW
WH-ADC0316M9E83
5,650
✔
✔
260 L
9 kW
WH-ADC0316M9E8AN3
6,997
✔
✔
—
3 kW
WH-SDC0916M3E5
1,567
✔
✔
✔
✔
✔
—
6 kW
WH-SDC0916M6E5
1,812
✔
✔
—
9 kW
WH-SDC0316M9E8
2,195
✔
✔
1ph
—
—
—
WH-CME5
1,445
✔
✔
3ph
—
—
—
WH-CME8
1,445
✔
✔
—
—
—
—
CZ-RTW2TAW1C
867
✔
✔
Outdoor unit
1ph
Heating capacity / COP
Cooling
capacity / EER
SCOP
Energy class
(heating)
Piping information
Sound
power 1)
Dimension
A +7 °C,
W 35 °C
A +7 °C,
W 55 °C
A 35 °C,
W 18 °C
W 35 °C /
W 55 °C
W 35 °C /
W 55 °C
Elevation
difference
(in / out)
m
Heat
HxWxD
A+++ to D
Pipe length
range
(std / max)
m
dB(A)
mm
kg
A+++ / A++
5 / 30
30
55
1 520 x 1 200 x 370
160
30
59
1 520 x 1 200 x 370
160
kW / COP
kW / COP
kW / EER
WH-WDG12ME5*
12,10 / 4,78
12,10 / 3,03
9,00 / 3,92
4,58 / 3,57
WH-WDG16ME5*
16,00 / 4,31
14,70 / 2,72
9,00 / 3,92
4,46 / 3,57
Indoor unit
Water
volume
Tentative
data 5 / 30
A+++ / A++
Weight
DHW tank
ERP
Piping information
Electrical information
Energy
class 2)
Water pipe connector
Electric
backup
heater
Recommended
fuse, supply 3)
Recommended H x W x D
minimum cable
size, supply 3)
kW
A
mm²
mm
kg
Dimension
Weight
Room
Shower
In / out
L
A+ to F
Inch
Inch
Inch
WH-ADC0916M3E51*
120
A
1¼
¾
1¼ / 1¼data 3,00
Tentative
16
3x1,5
1 293 x 599 x 602
74
WH-ADC0916M3E52
185
A+
1¼
¾
1¼ / 1¼
3,00
15 / 16
3x1,5
1 642 x 599 x 602
88
WH-ADC0916M6E52
185
A+
1¼
¾
1¼ / 1¼
6,00
30
3x4,0
1 642 x 599 x 602
88
WH-ADC0916M3E53
260
A+
1¼
¾
1¼ / 1¼
3,00
15 / 16
3x1,5
2 036 x 599 x 602
105
WH-ADC0916M6E53
260
A+
1¼
¾
1¼ / 1¼
6,00
30
3x4,0
2 036 x 599 x 602
105
WH-ADC0316M9E82
185
A+
1¼
¾
1¼ / 1¼
9,00
20
5x1,5
1 642 x 599 x 602
89
WH-ADC0316M9E83
260
A+
1¼
¾
1¼ / 1¼
9,00
20
5x1,5
2 036 x 599 x 602
105
WH-ADC0916M3E5AN1*
120
A
1¼
¾
1¼ / 1¼data 3,00
Tentative
16
3x1,5
1 293 x 599 x 602
74
WH-ADC0916M3E5AN2
185
A+
1¼
¾
1¼ / 1¼
3,00
15 / 16
3x1,5
1 642 x 599 x 602
88
WH-ADC0916M3E5AN3
260
A+
1¼
¾
1¼ / 1¼
3,00
15 / 16
3x1,5
2 036 x 599 x 602
105
WH-ADC0316M9E8AN2
185
A+
1¼
¾
1¼ / 1¼
9,00
20
5x1,5
1 642 x 599 x 602
89
WH-ADC0316M9E8AN3
260
A+
1¼
¾
1¼ / 1¼
9,00
20
5x1,5
2 036 x 599 x 602
105
WH-SDC0916M3E5
—
—
—
—
1¼ / 1¼
3,00
15 / 16
3x1,5
892 x 500 x 348
28
WH-SDC0916M6E5
—
—
—
—
1¼ / 1¼
6,00
30
3x4,0
892 x 500 x 348
28
WH-SDC0316M9E8
—
—
—
—
1¼ / 1¼
9,00
20
5x1,5
892 x 500 x 348
29
All in One
1ph
3ph
All in One with Electrical Anode
1ph
3ph
Bi-bloc
1ph
3ph
Control module
Field supply electrical
backup heater
Recommended fuse,
supply 3)
Recommended minimum
cable size, supply 3)
Connecting cable to the Dimension
outdoor unit size
HxWxD
Net weight
A
16
mm²
mm
kg
WH-CME5
kW
Up to 3 kW
mm²
1ph
3x1,5
2x0,75
454 x 520 x 116
7
3ph
WH-CME8
Up to 9 kW
30
3x4,0
2x0,75
454 x 520 x 116
7
1) Sound power level in accordance to EN 12102 under conditions of the EN 14825 (part load). 2) Scale from A+ to F. Energy class A with 16 kW outdoor unit. 3) Check local regulations. * Available Autumn 2025.
Tentative data. ** EER and COP calculation is based in accordance to EN 14511. *** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is
not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and
warranty costs related to these cases are the customer’s responsibility.
17