GENERAL INDEX
Aquarea High Performance Split
NEW Aquarea High Performance All in One 260L K Series.
Single phase with Electrical Anode · R32
Optional Wi-Fi adapter (CZ-TAW1C).
Indoor unit (H x W x D): 2 036 x 599 x 602 mm.
Operation range down to -25 °C 1) in heating.
New 2025
Optional
Indoor unit
WH-
RRP
Heating capacity /
COP
Cooling
capacity /
EER
Heating
W 35 °C / W 55 °C
DHW
A +7 °C,
W 35 °C
A +7 °C,
W 55 °C
A 35 °C,
W 18 °C
SCOP
Energy
class
Energy
class
kW / COP
kW / COP
kW / EER
A+++ to D
A+ to F
Outdoor unit
Weight
RRP
Sound
Dimension /
power 2) Weight
COPdhw
€ WH-
kg
Heat
HxWxD
dB(A)
mm / kg
€
All in One
ADC0912K6E53
12,10 / 4,78 12,00 / 2,96 10,70 / 3,92 4,58 / 3,33
A+++ / A++
A+
3,08
119
7,482
UDZ12KE5
65
1340x900x320/88
3,008
ADC16K6E53
16,00 / 4,31 14,70 / 2,72 13,00 / 3,80 4,46 / 3,46
A+++ / A++
A+
3,08
116
6,352
UDZ16KE5
65
1340x900x320/88
3,610
All in One with Electrical Anode
ADC0912K6E5AN3
12,10 / 4,78 12,00 / 2,96 10,70 / 3,92 4,58 / 3,33
A+++ / A++
A+
3,08
119
8,369
UDZ12KE5
65
1340x900x320/88
3,008
ADC16K6E5AN3
16,00 / 4,31 14,70 / 2,72 13,00 / 3,80 4,46 / 3,46
A+++ / A++
A+
3,08
116
9,007
UDZ16KE5
65
1340x900x320/88
3,610
Piping information
Electrical information (power supply to indoor)
Kit
kW
12,0
16,0
Piping diameter (liquid - gas)
Inch
¼-½
¼-⅝
Kit
kW
Single phase
12,0
16,0
Pipe length range
m
3 ~ 30 (3 ~ 50) 1)
3 ~ 30 (3 ~ 50) 3)
Electric backup heater
kW
6,00
6,00
Elevation difference (in / out)
m
20 (30) 1)
20
Recommended fuse 3)
A
30 / 30
30 / 30
Pre-charged pipe length
m
10
10
Additional gas amount
g/m
30
30
Recommended minimum
cable size, supply 1 / 2 3)
mm²
3x4,0 / 3x4,0
3x4,0 / 3x4,0
1) Operation range down to -25 °C in heating with 3 ~ 40 m pipe length range, operation range down to -15 °C in heating with 3 ~ 50 m pipe length range. 2) Sound power level in accordance to EN 12102 under
conditions of the EN 14825. 3) Check local regulations. * Available in Summer 2025. ** EER and COP calculation is based in accordance to EN 14511. *** This product is designed to comply with the European
drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other
impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.
Aquarea High Performance All in One 185 L K Series Single phase 2 zones · R32
Optional Wi-Fi adapter (CZ-TAW1C).
Indoor unit (H x W x D): 1 642 x 599 x 602 mm.
Operation range down to -25 °C 1) in heating.
Indoor unit
Optional
RRP Outdoor unit
Heating capacity /
COP
Cooling
capacity /
EER
Heating
W 35 °C / W 55 °C
DHW
A +7 °C,
W 35 °C
A +7 °C,
W 55 °C
A 35 °C,
W 18 °C
SCOP
Energy
class
Energy
class
WH
kW / COP
kW / COP
kW / EER
A+++ to D
A+ to F
kg
ADC0309K3E5B
3,20 / 5,33
—
—
5,07 / 3,47
A+++ / A++
A+
3,20
109
ADC0309K3E5B
5,00 / 5,10
5,00 / 3,03
5,00 / 4,90 5,12 / 3,63
A+++ / A++
A+
3,50
109
ADC0309K3E5B
7,00 / 4,86
7,00 / 2,92
6,70 / 4,72 4,90 / 3,62
A+++ / A++
A+
3,50
109
ADC0309K3E5B
9,00 / 4,55
8,90 / 2,93
9,00 / 4,18 4,44 / 3,41
A+++ / A++
A+
3,50
109
Piping information
Weight
RRP
Sound
Dimension /
power 2) Weight
COPdhw
Heat
HxWxD
€ WH-
dB(A)
mm / kg
6,159 UDZ03KE5
55
622 x 824 x 298 / 37
1,940
6,159 UDZ05KE5
55
795 x 875 x 380 / 55
2,103
6,159 UDZ07KE5
56
795 x 875 x 380 / 55
2,260
6,159 UDZ09KE5
56
795 x 875 x 380 / 55
2,406
€
Electrical information (power supply to indoor)
Kit
kW
3,0
5,0
7,0
9,0
Piping diameter (liquid - gas)
Inch
¼-½
¼-⅝
¼-⅝
¼-⅝
Kit
kW
3,0
5,0
7,0
9,0
3 ~ 40 /
3 ~ 50 1)
3 ~ 40 /
3 ~ 50 1)
Electric backup heater
kW
3,00
3,00
3,00
3,00
Recommended fuse 3)
A
16 / 16
16 / 16
25 / 16
25 / 16
mm²
3x1,5 /
3x1,5
3x1,5 /
3x1,5
3x2,5 /
3x1,5
3x2,5 /
3x1,5
Pipe length range
m
3 ~ 25
3 ~ 40 /
3 ~ 50 1)
Elevation difference (in / out)
m
20
30
30
30
Pre-charged pipe length
m
10
10
10
10
Additional gas amount
g/m
20
25
25
25
Single phase
Recommended minimum
cable size, supply 1 / 2 3)
1) Operation range down to -25 °C in heating with 3 ~ 40 m pipe length range, operation range down to -15 °C in heating with 3 ~ 50 m pipe length range. 2) Sound power in accordance to 811/2013, 813/2013 and
EN 12102-1:2017 at +7 °C. 3) Check local regulations. * EER and COP calculation is based in accordance to EN 14511. ** This product is designed to comply with the European drinking water standard
(EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in
areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.
30