GENERAL INDEX
Aquarea High Performance Split
NEW Aquarea High Performance All in One 260L K Series. Three phase · R32
Optional Wi-Fi adapter (CZ-TAW1C).
Indoor unit (H x W x D): 2 036 x 599 x 602 mm.
Operation range down to -25 °C in heating.
New 2025
Optional
Indoor unit
RRP Outdoor unit
Heating capacity /
COP
Cooling
capacity /
EER
Heating
W 35 °C / W 55 °C
DHW
A +7 °C,
W 35 °C
A +7 °C,
W 55 °C
A 35 °C,
W 18 °C
SCOP
Energy
class
Energy
class
WH-
kW / COP
kW / COP
kW / EER
A+++ to D
A+ to F
ADC0912K9E83
9,00 / 4,90 9,00 / 2,97 8,80 / 4,63 4,96 / 3,57
A+++ / A++
A+
ADC0912K9E83
12,10 / 4,78 12,00 / 2,96 10,70 / 3,92 4,58 / 3,33
A+++ / A++
A+
ADC16K9E83
16,00 / 4,31 14,70 / 2,72 15,50 / 3,60 4,46 / 3,40
A+++ / A++
A+
Piping information
RRP
Weight
Sound
Dimension /
power 1) Weight
COPdhw
Heat
HxWxD
kg
€ WH-
dB(A)
mm / kg
€
3,08
119
7,439 UDZ09KE8
65
1340x900x320/90
2,647
3,08
119
7,439 UDZ12KE8
65
1340x900x320/90
3,610
2,45
120
7,663 UDZ16KE8
65
1340x900x320/103
3,971
Electrical information (power supply to indoor)
Kit
kW
9,0
12,0
16,0
Single phase
Piping diameter (liquid - gas)
Inch
¼-½
¼-½
¼-½
Kit
kW
9,0
12,0
16,0
Pipe length range
m
3 ~ 30
3 ~ 30
3 ~ 30
Electric backup heater
kW
9,00
9,00
9,00
Elevation difference (in / out)
m
20
20
20
Recommended fuse 2)
A
20 / 20
20 / 20
20 / 20
Pre-charged pipe length
m
10
10
10
Additional gas amount
g/m
30
30
30
Recommended minimum
cable size, supply 1 / 2 2)
mm²
5x1,5 / 5x1,5
5x1,5 / 5x1,5
5x2,5 / 5x1,5
1) Sound power level in accordance to EN 12102 under conditions of the EN 14825. 2) Check local regulations. * EER and COP calculation is based in accordance to EN 14511. ** This product is designed to
comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water
when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.
NEW Aquarea High Performance All in One 260L K Series.
Three phase with Electrical Anode · R32
Optional Wi-Fi adapter (CZ-TAW1C).
Indoor unit (H x W x D): 2 036 x 599 x 602 mm.
Operation range down to -25 °C in heating.
New 2025
Optional
Indoor unit
RRP Outdoor unit
Heating capacity /
COP
Cooling
capacity /
EER
Heating
W 35 °C / W 55 °C
DHW
A +7 °C,
W 35 °C
A +7 °C,
W 55 °C
A 35 °C,
W 18 °C
SCOP
Energy
class
WH-
kW / COP
kW / COP
kW / EER
ADC0912K9E8AN3
9,00 / 4,90 9,00 / 2,97 8,80 / 4,63 4,96 / 3,57
Energy
class
A+++ to D
A+ to F
A+++ / A++
A+
Weight
COPdhw
3,08
RRP
Sound
Dimension /
power 1) Weight
Heat
HxWxD
kg
€ WH-
dB(A)
mm / kg
119
7,769 UDZ09KE8
65
1340x900x320/90
€
2,647
ADC0912K9E8AN3
12,10 / 4,78 12,00 / 2,96 10,70 / 3,92 4,58 / 3,33
A+++ / A++
A+
3,08
119
7,769 UDZ12KE8
65
1340x900x320/90
3,610
ADC16K9E8AN3
16,00 / 4,31 14,70 / 2,72 15,50 / 3,60 4,46 / 3,40
A+++ / A++
A+
2,45
120
7,931 UDZ16KE8
65
1340x900x320/103
3,971
Piping information
Electrical information (power supply to indoor)
Kit
kW
9,0
12,0
16,0
Piping diameter (liquid - gas)
Inch
¼-½
¼-½
¼-½
Kit
kW
Single phase
9,0
12,0
16,0
Pipe length range
m
3 ~ 30
3 ~ 30
3 ~ 30
Electric backup heater
kW
9,00
9,00
9,00
Elevation difference (in / out)
m
20
20
20
Recommended fuse 2)
A
20 / 20
20 / 20
20 / 20
Pre-charged pipe length
m
10
10
10
Additional gas amount
g/m
30
30
30
Recommended minimum
cable size, supply 1 / 2 2)
mm²
5x1,5 / 5x1,5
5x1,5 / 5x1,5
5x2,5 / 5x1,5
1) Sound power level in accordance to EN 12102 under conditions of the EN 14825. 2) Check local regulations. * EER and COP calculation is based in accordance to EN 14511. ** This product is designed to
comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water