UK BIGRAC GEN 26 LR - Flipbook - Page 37
RANGE
R32
CZ-RTC5B
COMMERCIAL
COMPATIBLE WITH ALL PANASONIC CONNECTIVITY SOLUTIONS. FOR
DETAILED INFORMATION GO TO THE CONTROL SYSTEMS SECTION
Optional:
CONEX wired
remote
controller,
white.
CZ-RTC6W/
BL/BLW2
CONEX wired
remote
controller,
black.
CZ-RTC6/BL/
BLW2
Infrared
remote
controller.
CZ-RWS3 +
CZ-RWRU3
Three phase
Kit
Remote controller
10,0 kW
12,5 kW
14,0 kW
KIT-100PU3Z8
KIT-125PU3Z8
KIT-140PU3Z8
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
Cooling capacity
Nominal (Min - Max)
kW
10,0 (3,0 - 11,5)
12,5 (3,2 - 13,5)
14,0 (3,3 - 15,0)
EER 1)
Nominal (Min - Max)
W/W
3,82 (2,88 - 5,36)
3,58 (2,81 - 5,33)
3,23 (2,73 - 5,32)
6,7 A++
265,8%
256,2%
kW
10,0
12,5
14,0
kW
2,62 (0,56 - 4,00)
3,49 (0,60 - 4,80)
4,34 (0,62 - 5,50)
SEER / ηs,c 2)
Pdesign
Input power
Nominal (Min - Max)
Annual energy consumption 3)
kWh/a
521
—
—
10,0 (3,0 - 14,0)
12,5 (3,3 - 15,0)
14,0 (3,4 - 16,0)
Heating capacity
Nominal (Min - Max)
kW
Heating capacity at -15 °C 4)
Max
kW
8,2
10,5
10,8
COP 1)
Nominal (Min - Max)
W/W
4,93 (3,59 - 5,36)
4,43 (3,57 - 5,50)
4,18 (3,33 - 5,48)
SCOP / ηs,h 2)
Pdesign at -10 °C
Input power
Nominal (Min - Max)
Annual energy consumption 3)
4,4 A+
157,0%
152,2%
kW
10,0
12,5
14,0 (at -7 °C)
kW
2,03 (0,56 - 3,90)
2,82 (0,60 - 4,20)
3,35 (0,62 - 4,80)
3 182
—
—
S-1014PU3E
S-1014PU3E
S-1014PU3E
38,0 / 29,0 / 20,0
kWh/a
Indoor unit
Air flow
Hi / Med / Lo
Moisture removal volume
36,0 / 26,0 / 18,0
37,0 / 27,0 / 19,0
L/h
m³/min
2,7
4,8
6,0
45 / 38 / 32
46 / 39 / 33
47 / 40 / 34
Sound pressure 5)
Hi / Med / Lo
dB(A)
Sound power
Hi / Med / Lo
dB(A)
60 / 53 / 47
61 / 54 / 48
62 / 55 / 49
Indoor (H x W x D)
mm
319 x 840 x 840
319 x 840 x 840
319 x 840 x 840
Panel (H x W x D)
mm
33,5 x 950 x 950
33,5 x 950 x 950
33,5 x 950 x 950
Indoor / Panel
kg
25 / 5
25 / 5
25 / 5
Mark 1
Mark 1
Mark 1
Dimension
Net weight
nanoe X Generator
Outdoor unit
U-100PZ3E8
U-125PZ3E8
U-140PZ3E8
V
380 - 400 - 415
380 - 400 - 415
380 - 400 - 415
Cool
A
4,35 - 4,15 - 4,00
5,65 - 5,35 - 5,15
7,00 - 6,65 - 6,40
Heat
A
3,40 - 3,20 - 3,10
4,55 - 4,35 - 4,15
5,40 - 5,15 - 4,95
Air flow
Cool / Heat
m³/min
73,0 / 73,0
82,0 / 80,0
84,0 / 82,0
Sound pressure
Cool / Heat (Hi)
dB(A)
52 / 52
55 / 55
56 / 56
Sound power
Cool / Heat (Hi)
dB(A)
70 / 70
73 / 73
74 / 74
Dimension
HxWxD
mm
996 x 980 x 370
996 x 980 x 370
996 x 980 x 370
kg
83
87
87
Inch (mm)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
Inch (mm)
5/8 (15,88)
Power supply
Current
Net weight
Liquid
Piping diameter
5/8 (15,88)
5/8 (15,88)
Pipe length range
Gas
m
5 ~ 50
5 ~ 50
5 ~ 50
Elevation difference (in / out) 8)
m
15 / 30
15 / 30
15 / 30
Pre-charged pipe length
m
30
30
30
Additional gas amount
g/m
45
45
45
Refrigerant (R32) / CO₂ Eq.
kg / T
2,40 / 1,62
2,80 / 1,89
2,80 / 1,89
Cool Min ~ Max
°C
-10 ~ +43
-10 ~ +43
-10 ~ +43
Heat Min ~ Max
°C
-15 ~ +24
-15 ~ +24
-15 ~ +24
Operating range
1) EER and COP calculation is based in accordance to EN 14511. 2) For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is
calculated based on EN 14825. 3) Factory setting. 4) The value is based on the interpolation. 5) The sound pressure of the units shows the value measured of the position 1,5 m below the unit. The sound
pressure is measured in accordance with Eurovent 6/C/006‑97 specification. 6) Connect the liquid socket tube (Ø6,35‑Ø9,52) to the liquid tubing side indoor unit. 7) Connect the gas socket tube (Ø12,70‑Ø15,88)
to the gas tubing side indoor unit. 8) Outdoor unit located lower / outdoor unit located higher. *Recommended fuse for the indoor 3 A. **Above values are in the case of nanoe™ X OFF.
Accessories
Accessories
CZ-RTC6W
CONEX wired remote controller (non-wireless), white
CZ-KPU3A
CZ-RTC6WBL
CONEX wired remote controller with Bluetooth®, white
CZ-KPU3B
NEW Standard panel, graphite black (RAL9011)
CZ-RTC6WBLW2
CONEX wired remote controller with Wi-Fi and Bluetooth®, white
CZ-RTC6
CONEX wired remote controller (non-wireless), black
PAW-PACR4
Interface to run up to 4 indoor unit groups on backup and
alternative run
CZ-RTC6BL
CONEX wired remote controller with Bluetooth®, black
CZ-RTC6BLW2
CONEX wired remote controller with Wi-Fi and Bluetooth®, black
PAW-WTRAY
Tray for condenser water compatible with outdoor elevation
platform
CZ-RTC5B
Wired remote controller with Econavi function
PAW-GRDBSE20
Outdoor base ground support for noise and vibration absorption
CZ-RWS3 +
CZ-RWRU3
Infrared remote controller and receiver
PAW-GRDSTD40
Outdoor elevation platform 400 x 900 x 400 mm
CZ-CAPWFC2
Commercial Wi-Fi Adaptor
R32
A++
A++
REFRIGERANT
8,1 SEER
4,9 SCOP
28%
Econavi exclusive panel, white (RAL9003)
CZ-FDU3+CZ-ATU2 Fresh air-intake kit
-10 °C
-15 °C
COOLING MODE
HEATING MODE
R22
R410A
DC FAN
R32
R22 / R410A
RENEWAL
OPTIONAL WI-FI
BMS
CONNECTIVITY
5
YEARS
COMPRESSOR
WARRANTY
SEER: For S‑3650PU3E + U‑36PZ3E5. SCOP: For S‑6071PU3E + U‑60PZ3E5A. ECONAVI and INTERNET CONTROL: Optional.
Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.