UK BIGRAC GEN 26 LR - Flipbook - Page 38
GENERAL
R32
PACi NX Series Elite ceiling ‑ PT3 · R32
Ceiling mounted units provide large and wide air distribution which is
ideal for large rooms.
The height and depth of all capacities are the same for unified
appearance in mixed installations.
nanoe™ X as a standard.
Single phase
Kit
Remote controller
Cooling capacity
Nom (Min - Max)
kW
EER 1)
Nom (Min - Max)
W/W
SEER / ηs,c 2)
Pdesign
Input power
Nom (Min - Max)
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
CZ-RTC5B
3,5 (1,2 - 4,0)
5,0 (1,2 - 5,6)
6,0 (1,2 - 7,1)
6,8 (2,2 - 9,0)
9,5 (3,1 - 12,5)
12,1 (3,2 - 14,0)
13,4 (3,3 - 16,0)
4,86 (4,55 - 5,45) 4,03 (3,57 - 5,45) 3,82 (3,02 - 5,45) 3,91 (2,69 - 5,79) 4,06 (3,29 - 5,34) 3,46 (3,01 - 5,33) 3,21 (2,67 - 5,32)
7,3 A++
278,4%
9,5
12,1
13,4
kW
0,72 (0,22 - 0,88)
1,24 (0,22 - 1,57)
1,57 (0,22 - 2,35)
1,74 (0,38 - 3,35)
2,34 (0,58 - 3,80)
3,50 (0,60 - 4,65)
4,17 (0,62 - 6,00)
160
237
280
326
456
—
—
4,0 (1,2 - 5,0)
5,6 (1,2 - 6,5)
7,0 (1,2 - 8,0)
8,0 (2,0 - 9,0)
11,2 (3,1 - 14,0)
14,0 (3,2 - 16,0)
16,0 (3,3 - 18,0)
3,2
4,1
5,1
7,5
11,9
13,4
15,0
5,00 (4,17 - 5,45) 4,03 (3,94 - 5,45) 4,14 (3,40 - 5,45) 3,96 (3,16 - 5,56) 4,00 (3,54 - 5,54) 3,78 (3,20 - 5,52) 3,38 (3,10 - 5,50)
4,9 A++
4,8 A++
4,8 A++
4,7 A++
4,5 A+
175,6%
3,1
4,0
4,6
4,7
7,8
9,5
10,2
kW
0,80 (0,22 - 1,20)
1,39 (0,22 - 1,65)
1,69 (0,22 - 2,35)
2,02 (0,36 - 2,85)
2,80 (0,56 - 3,95)
3,70 (0,58 - 5,00)
4,74 (0,60 - 5,80)
kWh/a
m³/min
886
1 167
1 342
1 400
2 426
—
—
S-3650PT3E
S-6071PT3E
S-6071PT3E
S-1014PT3E
S-1014PT3E
S-1014PT3E
14,0 / 12,0 / 10,5 15,0 / 12,5 / 10,5 20,0 / 17,0 / 14,5 21,0 / 18,0 / 15,5 30,0 / 25,0 / 23,0 34,0 / 28,0 / 24,0 35,0 / 29,0 / 25,0
L/h
0,8
2,0
2,1
2,7
3,6
5,4
6,4
dB(A)
36 / 32 / 28
37 / 33 / 28
38 / 34 / 29
39 / 35 / 30
42 / 37 / 34
46 / 40 / 35
47 / 41 / 36
56 / 52 / 47
57 / 53 / 48
60 / 55 / 52
64 / 58 / 53
65 / 59 / 54
Hi / Med / Lo
Sound power
Hi / Med / Lo
dB(A)
54 / 50 / 46
55 / 51 / 46
Dimension
HxWxD
mm
235 x 960 x 690
235 x 960 x 690
kg
nanoe X Generator
Outdoor unit
235 x 1 275 x 690 235 x 1 275 x 690 235 x 1 590 x 690 235 x 1 590 x 690 235 x 1 590 x 690
26
26
34
34
40
40
40
Mark 2
Mark 2
Mark 2
Mark 2
Mark 2
Mark 2
Mark 2
U-140PZH4E5
U-36PZH3E5
U-50PZH3E5
U-60PZH3E5
U-71PZH4E5
U-100PZH4E5
U-125PZH4E5
V
220 - 230 - 240
220 - 230 - 240
220 - 230 - 240
220 - 230 - 240
220 - 230 - 240
220 - 230 - 240
220 - 230 - 240
Cool
A
3,55 - 3,40 - 3,25 5,85 - 5,60 - 5,40 7,35 - 7,05 - 6,75 8,80 - 8,40 - 8,05
11,60-11,10-10,60
17,10-16,40-15,70
20,40-19,50-18,70
3,90 - 3,75 - ,3,60 6,60 - 6,30 - 6,05 7,85 - 7,50 - 7,20
Power supply
Heat
A
10,20-9,75-9,35
13,70-13,20-12,70
18,10-17,30-16,60
23,20-22,20-21,20
Air flow
Cool / Heat
m³/min
34,1 / 36,4
42,0 / 42,0
42,0 / 42,0
62,0 / 66,0
76,0 / 70,0
86,0 / 78,0
89,0 / 83,0
Sound pressure
Cool / Heat (Hi)
dB(A)
43 / 44
46 / 48
47 / 50
48 / 50
52 / 52
55 / 55
56 / 56
Sound power
Cool / Heat (Hi)
dB(A)
62 / 64
64 / 67
65 / 69
65 / 67
69 / 69
73 / 73
74 / 74
Dimension
HxWxD
mm
695 x 875 x 320
695 x 875 x 320
695 x 875 x 320
996 x 980 x 370
996 x 980 x 370
996 x 980 x 370
996 x 980 x 370
Net weight
Piping diameter
kg
Liquid
Gas
42
42
43
66
84
86
86
Inch (mm)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35) 6)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
Inch (mm)
1/2 (12,70)
1/2 (12,70)
1/2 (12,70) 7)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
Pipe length range
m
3 ~ 40
3 ~ 40
3 ~ 40
5 ~ 60
5 ~ 100
5 ~ 100
5 ~ 100
Elevation difference (in / out) 8)
m
15 / 30
15 / 30
15 / 30
15 / 30
15 / 30
15 / 30
15 / 30
Pre-charged pipe length
m
30
30
30
30
30
30
30
Additional gas amount
g/m
15
15
15
30
40
40
40
Refrigerant (R32) / CO₂ Eq.
kg / T
1,13 / 0,76
1,13 / 0,76
1,15 / 0,78
1,95 / 1,32
2,70 / 1,82
3,00 / 2,03
3,00 / 2,03
Cool Min ~ Max
°C
-15 ~ +46
-15 ~ +46
-15 ~ +46
-15 ~ +52
-20 9) ~ +52
-20 9) ~ +52
-20 9) ~ +52
Heat Min ~ Max
°C
-20 ~ +24
-20 ~ +24
-20 ~ +24
-20 ~ +24
-20 ~ +24
-20 ~ +24
-20 ~ +24
Operating range
Technical focus
· Wide air distribution for large rooms
· Horizontal air flow reaches maximum 9,5 m
· Fresh air connection available on the unit
· Slim design with 235 mm height fits narrow space
· Silent operation
· nanoe™ X (Generator Mark 2: 9,6 trillion hydroxyl
radicals/sec) as standard for better indoor air quality
· Wired remote control CZ-RTC6WBL and CZ-RTC6BL
allows easy system setting via Bluetooth®
· Twin, Triple and Double-twin split options
· Easy connection and control of external fan or ERV using
the connector PAW-FDC on the indoor unit PCB. The
external device can be controlled by the remote control of
the Panasonic indoor unit
38
169,3%
S-3650PT3E
Sound pressure 5)
Current
263,3%
kW
Indoor unit
Net weight
14,0 kW
6,8
SCOP / ηs,h 2)
Hi / Med / Lo
12,5 kW
7,3 A++
W/W
Air flow
10,0 kW
6,0
kW
Moisture removal volume
7,1 kW
KIT-71PT3ZH45 KIT-100PT3ZH45 KIT-125PT3ZH45 KIT-140PT3ZH45
7,5 A++
COP 1)
Annual energy consumption 3)
KIT-60PT3ZH5
5,0
Heating capacity at -15 °C 4) Max
Nom (Min - Max)
KIT-50PT3ZH5
7,4 A++
kW
Input power
KIT-36PT3ZH5
3,5
kWh/a
Pdesign at -10 °C
6,0 kW
7,7 A++
Heating capacity
Nom (Min - Max)
5,0 kW
kW
Annual energy consumption 3)
Nom (Min - Max)
3,6 kW
Further comfort improvement with air flow
distribution
Horizontal air flow reaches maximum 9,5 m. This is ideal
for wide rooms.
The wide air discharge opening expands the air flow to the
left and right. The unpleasant feeling caused when the air
flow directly hits the human body is prevented by the
“Draft prevention position”, which changes the swing
width, increasing the degree of comfort.