UK Commercial 25 - Product brochure - Page 89
DIMENSIONS: COMMERCIAL
DIMENSIONS INDEX
PACi NX Series ceiling (S-6071PT3E).
123
61
Distance of each exposed bolt
must be of equal length within
50 mm
0 (c
3,1
4-Ø
utou
t)
Unit
Within 50
190
Ø10
Suspension bolt
114
Detailed view of air inlet duct
connection port
265 (suspension
bolt pitch)
73
7
Ceiling surface
Ø113
Bracket
1226 (suspension bolt pitch)
1269
250 or
more
250 or
more
1275
Service
space
690
1
8
216
80
186
13
216
Obstacles
Air outlet
Minimum 50 cm
Air inlet
235
131
Approx. 2°
9
193
4
15
Service
space
2
2,2 m or more
250 or less
90 (closed with rubber
stopper at time of shipment)
(left drain position)
86 (gas piping)
3
4
70 (liquid piping)
90 (right drain position)
Side view
Hole position of indoor unit rear-side (figure shows view
from front)
120
97
123
70
5
86
90
Drain piping connection port VP20
2
3
4
5
6
7
8
9
10
11
12
13
14
Left drain position
Refrigerant piping (liquid)
Refrigerant piping (gas)
Cover of rear piping hole
Piping hole on wall surface
Upper side piping port
Right side drain hose outlet port (cutout)
Left side drain hose outlet port (cutout)
Left-rear side drain hose outlet port (cutout)
Power inlet port
Remote control wiring and inter-unit wiring inlet port
Wireless remote controller receiver installation location
Air inlet duct connection port
Ø9,52 (flared) 1)
Ø15,88 (flared) 2)
235
131
90
11
Inside diameter 26 mm,
drain hose supplied
12
Piping hole position on wall surface (figure shows view
from front)
Ø100 mm
176
1
10
196
185
105
196
14
6
96
Ø100 mm (cutout)
1) When connecting with U-60PZ3E5, U-71PZ3E5 or U-60PZH3E5, connect the liquid socket piping (Ø9,52 - Ø6,35) to the
liquid piping side indoor unit.
2) When connecting with U-60PZ3E5 or U-60PZH3E5, connect the gas socket piping (Ø15,88 - Ø12,70) to the gas piping side
indoor unit.
Filter dimension: 579 x 250 x 16 mm x 2 pcs.
Unit: mm
89