NEW! ECOi-W AQUA-G EVO 60-110 H · R290
R290
Air cooled heat pumps Inverter.
NATURAL
REFRIGERANT
Cooling capacity: 56,7 to 91,0 kW.
Heating capacity: 61,2 to 101,9 kW.
The range at a glance
· 1 version: H (heat pump)
· 3 sizes
· 2 acoustic options: STD (standard) and S (super low
noise)
Advantages
NEW
· Natural refrigerant R290
· Inverter driven compressor
· Very high performance
· Improved heating capacity at low ambient temperature
· Expanded operating limit
· Domestic Hot Water management
· Compact chassis
· Very quiet operation
· Modular configuration with integrated main/sub logic
· Ultra-compact design allows multiple units to be
installed side by side with minimal spacing.
· SG Ready
· Reliable safety measurements
· Suitable for boiler replacement with DT 12 °C in heating
Operating limits
To be confirmed with AC SELECT:
https://acselect.panasonic.eu/
Equipment
Ambient temperature.
‑18 °C
48 °C
Tentative data
‑18 °C
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40 °C
40
45
50
55
Leaving water temperature.
‑10 °C 1)
20 °C
Tentative data
20 °C
-20
-10
0
10
1) With glycol, 5 °C without glycol.
24
20
30
40
50
75 °C
60
70
80
· Fan speed control. All units are equipped with EC fan
technology and flow grid to reduce Sound power
· Electronic expansion valve. This reliable and highperformant valve minimises overheating of the
evaporator. It is directly managed by the control system
· Compressor: 1 inverter compressor for size 60 and
tandem compressor (fixed + Inverter) for sizes 80-110
· Compressor box providing both protection and noise
reduction
· Automatic circuit breakers
· Integrated HMI to manage unit operation
· An advanced built-in controller enabling fully
autonomous operation
· Communication protocol: Modbus RTU, Modbus TCP/IP
· Highly optimised finned tube Al/Cu heat exchanger with
Bluefin treatment
· Condensate drain pan to collect and direct the
condensate away from the unit
· Antifreeze electric heater on the plate heat exchanger
· Pressure relief valve
· Differential pressure switch on the plate heat exchanger
from water side
· Water expansion vessel (only with pump and/or tank)
· Leak detector and safety ventilation fans to detect R290
leakages and exhaust refrigerant to atmosphere in the
event of a leak
· DHW function available on the controller with DHW probe
and 3 way valve available as options
· Removable panels. Great accessibility to internal
components for service operations
· Multiple lifting point (lateral, frontal and upper side) for
an easy handling of the unit