UK HYDRONICS GEN 26 - Flipbook - Page 31
RANGE
R32
CHILLERS AND HEAT PUMPS
Technical performance
Voltage
Power
supply
V
Phase
Frequency
Hz
Size
400
400
400
400
400
400
400
400
400
400
Three
phase
Three
phase
Three
phase
Three
phase
Three
phase
Three
phase
Three
phase
Three
phase
Three
phase
Three
phase
50
50
50
50
50
50
50
50
50
50
50
60
70
75
85
100
115
130
150
170
0170
ECOi-W AQUA-Z 50-170 C - chiller
P-AQAZ****CA
0050
0060
0070
0075
0085
0100
0115
0130
0150
Cooling capacity 1)
kW
51,6
57,6
69,7
78,2
82,8
100
116
126
154
173
Input power 1)
kW
16,5
19,6
22,4
24
26,8
31,4
37,4
42,3
47,4
55,7
2,94 / 3,03
3,11 / 3,29
3,26 / 3,41
3,09 / 3,23
3,18 / 3,30
3,10 / 3,20
2,98 / 3,07
3,25 / 3,38
3,11 / 3,20
EER (STD AC / STD EC) *1)
3,13 / 3,25
SEER (STD AC / STD EC) *2) 3)
4,60 / 5,05 4,59 / 5,02 4,61 / 5,31 4,72 / 5,29 4,45 / 4,96 4,88 / 5,19 4,59 / 5,01 4,43 / 4,71 4,70 / 5,22 4,68 / 5,16
ηs,c (STD AC / STD EC) *2) 3)
180,9 /
198,9
180,5 /
197,8
181,3 /
209,6
185,6 /
208,7
175,0 /
195,6
192,3 /
204,9
180,5 /
197,3
174,2 /
185,6
184,8 /
205,6
184,2 /
203,2
Nominal water flow (in the evaporator)
m³/h
9,2
10,6
12,2
13,2
14,7
17,9
21,1
23,5
27,2
30,7
Sound power (STD AC / S) *
dB(A)
83 / 81
84 / 81
81 / 78
81 / 78
84 / 82
86 / 83
87 / 84
87 / 84
89 / 86
91 / 88
Sound pressure at 10 m (STD AC / S) *4)
dB(A)
51 / 49
52 / 49
50 / 47
49 / 46
52 / 50
54 / 51
55 / 52
55 / 53
57 / 54
59 / 56
ECOi-W AQUA-Z 50-170 H - heat pump
P-AQAZ****HA
0050
0060
0070
0075
0085
0100
0115
0130
0150
0170
Cooling capacity 1)
51,1
57
69
77,4
82
99,3
115
125
152
170
Input power 1)
16,7
19,8
22,6
24,3
27,1
31,8
37,7
42,7
47,9
57,1
EER (STD AC / STD EC) *1)
3,06 / 3,17
2,88 / 2,97
3,05 / 3,22
3,19 / 3,35
3,03 / 3,17
3,12 / 3,25
3,05 / 3,14
2,93 / 3,00
3,17 / 3,30
2,98 / 3,07
EER (STD AC / STD EC) *5)
3,53 / 3,67
3,40 / 3,50
3,57 / 3,64
3,78 / 3,96
3,52 / 3,66
3,63 / 3,76
3,51 / 3,54
3,39 / 3,50
3,63 / 3,76
3,39 / 3,56
SEER (STD AC / STD EC) *2)
4,46 / 4,83 4,42 / 4,50 4,51 / 5,04 4,61 / 4,99 4,33 / 4,80 4,77 / 4,93 4,44 / 4,82 4,23 / 4,51 4,59 / 5,04 4,49 / 4,92
ηs,c (STD AC / STD EC) *2)
175,2 /
190,2
173,6 /
176,9
177,5 /
198,8
181,5 /
196,7
170,3 /
188,9
187,7 /
194,1
174,6 /
190,0
166 /
177,2
180,5 /
198,7
176,6 /
193,8
Nominal water flow (in the evaporator)
m³/h
8,7
10,6
12,2
13,2
14,7
17,9
21,1
23,5
27,2
30,7
Heating capacity 6)
kW
51,7
59,7
71,8
78,5
86,5
107,6
122,3
137,5
159,1
180,1
Input power 6)
kW
17,1
19,9
22,9
25,0
28,0
33,6
38,2
42,4
49,8
56,2
3,01 / 3,27
2,99 / 3,21
3,13 / 3,43
3,13 / 3,19
3,08 / 3,30
3,20 / 3,45
3,20 / 3,42
3,24 / 3,42
3,19 / 3,48
3,20 / 3,40
COP (STD AC / STD EC) *7)
3,81 / 4,00
3,80 / 3,92
3,92 / 4,21
3,91 / 4,16
3,92 / 4,16
3,99 / 4,19
4,10 / 4,26
4,04 / 4,12
4,07 / 4,31
4,02 / 4,16
SCOP (STD AC / STD EC) *2) 8)
3,53 / 3,90 3,54 / 3,94 3,47 / 3,71 3,65 / 3,80 3,60 / 4,02 3,64 / 4,10 3,66 / 4,02 3,72 / 3,97 3,57 / 4,04 3,60 / 3,95
COP (STD AC / STD EC) *6)
Energy efficiency class (STD AC /
STD EC) *2) 7)
A+++ to D
ηs,h (STD AC / STD EC) *2) 7)
A+ / A+
A+ / A+
A+ / A++
A+ / A++
A+ / A++
—/—
—/—
—/—
—/—
—/—
138,0 /
152,8
138,5 /
154,5
135,6 /
145,3
143,2 /
148,8
141,2 /
157,8
142,5 /
160,9
143,2 /
157,9
145,7 /
155,9
139,9 /
158,4
140,9 /
155,2
Nominal water flow (in the evaporator)
m³/h
9,3
10,7
12,5
13,9
15,0
18,3
21,5
23,9
27,5
31,7
Sound power (STD AC / S) *
dB(A)
83 / 81
84 / 81
81 / 78
81 / 78
84 / 82
86 / 83
87 / 84
87 / 84
89 / 86
91 / 88
Sound pressure at 10 m (STD AC / S) *4)
dB(A)
51 / 49
52 / 49
50 / 47
50 / 46
52 / 50
54 / 51
55 / 52
56 / 53
57 / 54
59 / 56
50
60
70
75
85
100
115
130
150
170
Physical features
ECOi-W AQUA-Z 50-170 C/H - chiller / heat pump
Dimension
Height (STD / EC/HPF)
mm
Width
mm
1 160
1 160
1 160
1 160
1 160
1 160
1 160
1 160
1 151
Length without water tank mm
2 180
2 180
2 180
2 180
2 180
2 180
2 180
2 180
3 789
3 789
527
547
621
637
701
731
813
815
1 265
1 279
Male gas
threaded
BSPP ISO
228
Male gas
threaded
BSPP ISO
228
Male gas
threaded
BSPP ISO
228
Male gas
threaded
BSPP ISO
228
Male gas
threaded
BSPP ISO
228
Male gas
threaded
BSPP ISO
228
Male gas
threaded
BSPP ISO
228
Male gas
threaded
BSPP ISO
228
Male gas
threaded
BSPP ISO
228
Male gas
threaded
BSPP ISO
228
2
2
2
2
2½
2½
2½
2½
2½
2½
Operating weight without water tank - 1
pump
1986 / 2034 1986 / 2034 1986 / 2034 1986 / 2034 2286 / 2334 2286 / 2334 2286 / 2334 2286 / 2334 2285 / 2333 2285 / 2333
kg
1 151
Water connections
Type of connections (evaporator)
Inlet/outlet diameter
Inch
1) According to EN 14511‑2018: chilled water inlet/outlet temperature: 12/7 °C, outdoor ambient temperature 35 °C DB. 2) According to EN 14825. 3) ErP compliant: following COMMISSION REGULATION (EU)
2016/2281. 4) Sound pressures refer to ISO 3744 standard, parallelepiped shape. 5) According to EN 14511‑2018: chilled water inlet/outlet temperature: 23/18 °C, outdoor ambient temperature 35 °C DB.
6) According to EN 14511‑2018: warm water inlet/outlet temperature: 40/45 °C, outdoor ambient temperature 7 °C DB/6 °C WB. 7) According to EN 14511‑2018: warm water inlet/outlet temperature: 30/35 °C,
outdoor ambient temperature 7 °C DB/6 °C WB. 8) ErP compliant: following COMMISSION REGULATION (EU) No 813/2013.
*STD AC: standard version with AC fan, STD EC: standard version with high‑efficiency EC fan, S: super low noise version with high‑efficiency EC fan + compressor sound jackets.
Accessories and options
Accessories and options
Accessories and options
Anti-vibration rubber mount / spring dampers *
Outdoor coil protection grid
Water tank 300 L
Compressor jackets (standard for S versions)
Power factor corrector capacitors
Without neutral
Desuperheater
Refrigerant gauges HP/LP
Electric heater for the water tank
Shut off valves
Communication protocols: Modbus RTU (Std.), Modbus
TCP/IP, BACnet MSTP, BACnet IP
Fin&Tube Al/Cu with epoxy / Blygold treatment
Soft starter
High efficiency EC fan
Variable speed pumps
High pressure fan (HPF)
Water pressure switch *
*Field‑installed accessories. All other accessories are factory‑installed.
Accessories supplied loose
Accessories supplied loose
P-375281
SRC – mini BMS controller
P-372615
Kit 4G modem
P-586595
Cascade controller
SVC-HYD-COMM-CLD1
1-year pre-paid Cloud access
P-372061
Remote keyboard panel
SVC-HYD-COMM-CLD3
3-year pre-paid Cloud access
R32
REFRIGERANT
ErP
✔
HIGH
SEER
HIGH
SCOP
5,22
4,10
AIR
COOLED
PLATE HEAT
EXCHANGER
SCROLL
COMPRESSOR
SUPER QUIET
VERY HIGH
PERFORMANCE
COMMERCIAL
SMART EDGE
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.