UK HYDRONICS GEN 26 - Flipbook - Page 37
RANGE
R410A
CHILLERS AND HEAT PUMPS
Technical performance
Voltage
V
Phase
Power supply
Frequency
Hz
Size
ECOi-W AQV 85-140 C - chiller
400
400
400
400
400
400
Three phase
Three phase
Three phase
Three phase
Three phase
Three phase
50
85
50
95
50
105
50
115
50
125
50
140
P-AQVE0085CA
P-AQVE0095CA
P-AQVE0105CA
P-AQVE0115CA
P-AQVE0125CA
P-AQVE0140CA
Cooling capacity 1)
kW
83,5
93,6
103,0
110,1
121,9
136,6
Input power 1)
kW
26,9
31,0
33,5
36,5
41,1
46,1
3,10
3,03
3,06
3,03
2,98
2,97
EER HSE 1)
3,19
3,10
3,13
3,09
3,05
3,04
SEER 2) 3)
ηs,c 2) 3)
4,55
4,8
4,78
4,8
4,73
4,53
179
189
188
189
186
178
SEER HSE 2) 3)
ηs,c HSE 2) 3)
4,73
4,75
4,95
4,95
4,78
4,6
186
187
195
195
188
181
23,5
EER 1)
Nominal water flow (in the evaporator)
m³/h
14,3
16,1
17,6
19,0
21,0
Sound power 4)
dB(A)
84
84
84
84
88
88
Sound pressure at 10 m 5)
dB(A)
52
52
52
52
56
56
Sound power HPF 4)
dB(A)
92
92
92
92
95
95
Sound pressure at 10 m HPF 5)
dB(A)
60
60
60
60
63
63
85
95
105
115
125
140
Cooling capacity 1)
kW
80,6
90,2
98,6
106
119,1
133,1
Input power 1)
kW
ECOi-W AQV 85-140 C S - chiller
EER 1)
28
32,6
35,5
38,6
41,1
46,5
2,87
2,76
2,77
2,73
2,90
2,86
2,91
EER HSE 1)
3,00
2,87
2,87
2,81
2,96
SEER 2) 3)
ηs,c 2) 3)
4,75
4,78
4,98
5,0
4,8
4,6
187
188
196
197
189
181
SEER HSE 2) 3)
ηs,c HSE 2) 3)
4,8
4,75
4,88
4,88
4,9
4,7
189
187
192
192
193
185
22,9
Nominal water flow (in the evaporator)
m³/h
13,9
15,5
16,9
18,2
20,5
Sound power 4)
dB(A)
82
82
82
82
86
86
Sound pressure at 10 m 5)
dB(A)
50
50
50
50
54
54
85
95
105
115
125
140
Cooling capacity 1)
kW
86,2
96,9
107
115
124
139
Input power 1)
kW
28,1
31,6
33,9
36,4
41,1
46
EER 1)
3,07
3,06
3,15
3,16
3,03
3,03
SEER 2) 3)
ηs,c 2) 3)
4,73
4,75
4,95
4,95
4,78
4,6
186
187
195
195
188
181
24,0
ECOi-W AQV 85-140 C HT - chiller
Nominal water flow (in the evaporator)
m³/h
14,8
16,6
18,3
19,8
21,4
Sound power 4)
dB(A)
95
95
95
95
95
95
Sound pressure at 10 m 5)
dB(A)
63
63
63
63
63
63
1) According to EN 14511‑2013: chilled water inlet/outlet temperature: 12/7 °C, outdoor ambient temperature 35 °C DB. 2) ErP compliant: following COMMISSION REGULATION (EU) 2016/2281. 3) According to
EN 14825. 4) Sound levels are at fully loaded conditions. Sound power values refers to ISO 3744 standard. 5) Sound pressures refer to ISO 3744 standard, parallelepiped shape.
Accessories and options
Accessories and options
Anti-vibration spring dampers
Overload protection for compressors
Automatic circuit breaker
Power factor corrector capacitors
Coils treatments
Several communication protocols
Desuperheater
Soft starter
Fan speed control
Unit protection grilles
Hydrokit with 1 or 2 pumps with or without buffer tank
Water differential pressure
Mechanical gauges
Accessories supplied loose
Accessories supplied loose
P-376463
Sequencer for up to 4 chillers installation
P-347999
Chiller grilles for sizes 85-115
P-347941
Remote ON / OFF
P-347998
Chiller grilles for sizes 125-140
P-364735
Remote keyboard panel
P-473465
Pressure switch
P-348000
Coil guards for sizes 85-115
P-348615
Water filter for sizes 85-105
P-348001
Coil guards for sizes 125-140
P-348616
Water filter for sizes 115-140
ErP
✔
HIGH
SEER
HIGH
SCOP
5,00
4,12
AIR
COOLED
PLATE HEAT
EXCHANGER
SCROLL
COMPRESSOR
VERY HIGH
PERFORMANCE
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.