UK INTRO-AQUAREA GEN 24 - Flipbook - Page 73
R290
AQUAREA INDEX
NEW Aquarea Loop · R290
· Compact indoor unit – depth of only 140 mm
· DC Inverter compressor with R290
· Cooling in summer
· Use of low centralised loop water temperature of
20 - 30 °C all year round
· Use of existing piping for renovations*
AQUAREA
New
2024
* Based on the low flow rate requirement – must be checked on each project.
R290
Technical features
Model (the complete model codes are shown in the table below)
Cooling capacity 1)
Nominal (Min - Max)
EER
kW
W/W
SEER
Input power cooling
1)
Heating capacity 2)
Nominal (Min - Max)
COP
P‑CWSL20
P‑CWSL30
1,50 (0,30 - 1,70)
2,60 (0,60 - 3,00)
4,40
4,80
4,80
5,50
6,10
7,90
kW
0,2
0,3
0,5
kW
1,10 (0,40 - 1,40)
2,00 (0,40 - 2,30)
3,10 (0,80 - 3,60)
W/W
SCOP
Input power 2)
P‑CWSL10
1,10 (0,20 - 1,20)
kW
5,20
5,40
5,90
6,44
6,92
6,74
0,2
0,4
0,5
Ventilation
Ventilation speeds
Air flow
Min / Ave / Max
m³/h
Voltage
V
4
4
4
50 / 105 / 160
100 / 205 / 330
175 / 305 / 500
Electrical data
Power supply
Phase
Frequency
230
230
230
Single phase
Single phase
Single phase
Hz
50
50
50
Maximum input current
A
1,74
3,87
5,01
Max consumption
kW
0,40
0,89
1,15
Sound levels
Sound power 3)
Max
dB(A)
48
50
52
Sound pressure 4)
Min / Nom / Max
dB(A)
28 / 33 / 40
29 / 34 / 42
31 / 35 / 44
Eurokonus
Hydraulic data
Connection type
Eurokonus
Eurokonus
Inch
¾
¾
¾
Heating
L/min
3,7
7,7
12,0
Cooling
L/min
4,5
5,2
9,0
Heating
kPa
6,80
11,20
12,50
Hydraulic connections
Water flow rate
Nominal pressure drop
Nominal pressure drop
with flow control valve
Cooling
kPa
4,80
5,40
7,50
Heating
kPa
7,80
14,20
20,50
Cooling
Refrigerant (R290)
kPa
5,40
6,70
11,80
kg
0,10
0,14
0,15
641 x 775 x 144
641 x 975 x 144
641 x 1 225 x 144
35
40
45
Dimensions and weight
Dimensions
HxWxD
Empty weight
mm
kg
Operating range and water outlet
Operating range - indoor
air
Water outlet
Heating
°C
5 ~ 27
5 ~ 27
5 ~ 27
Cooling
°C
18 ~ 35
18 ~ 35
18 ~ 35
Heating
°C
10 ~ 45
10 ~ 45
10 ~ 45
Cooling
°C
15 ~ 50
15 ~ 50
15 ~ 50
1) Loop water temperature 30 °C - Ambient air temperature 27 °C, indoor humidity 38% - Performance according to EN 14511. 2) Ring water temperature 20 °C - Ambient air temperature 20 °C, indoor humidity
50% - Performance according to EN 14511. 3) Sound power measured according to EN 16583. 4) Sound pressure at a distance of 1 m measured according to ISO 7779. * Available in Winter 24/25.
Aquarea Loop with on‑board display
Hydraulic
configuration
Without valves
P‑CWSL10SC5‑HCE
P‑CWSL20SC5‑HCE
Without valves + injection kit
P‑CWSL10SC5‑HFE
P‑CWSL20SC5‑HFE
P‑CWSL30SC5‑HFE
2 and 3 way valve with modulation
P‑CWSL10SC5‑HBE
P‑CWSL20SC5‑HBE
P‑CWSL30SC5‑HBE
2 and 3 way valve with modulation +
injection kit
P‑CWSL10SC5‑HEE
P‑CWSL20SC5‑HEE
P‑CWSL30SC5‑HEE
Without valves
P‑CWSL10SC5‑WCE
P‑CWSL20SC5‑WCE
P‑CWSL30SC5‑WCE
Without valves + injection kit
P‑CWSL10SC5‑WFE
P‑CWSL20SC5‑WFE
P‑CWSL30SC5‑WFE
2 and 3 way valve with modulation
P‑CWSL10SC5‑WBE
P‑CWSL20SC5‑WBE
P‑CWSL30SC5‑WBE
2 and 3 way valve with modulation +
injection kit
P‑CWSL10SC5‑WEE
P‑CWSL20SC5‑WEE
P‑CWSL30SC5‑WEE
P‑CWSL30SC5‑HCE
Aquarea Loop with on‑board display with integrated Wi‑Fi
Hydraulic
configuration
73