CO2
REFRIGERATION INDEX
REFRIGERATION
Superior cooling capacity at each evaporating temperature.
CO2 transcritical condensing units - CR Series have a high cooling capacity at each set point. The CO2 2-stage compressor
developed by Panasonic is designed to compress CO2 refrigerant twice; it reduces the load in operation by half (compared
to 1-stage refrigerant compression) and delivers increased durability and reliability.
Units can be programmed to run at low and medium temperatures at initial set-up. These settings can then be modified by
turning a simple and user friendly rotary switch to further enhance energy savings.
MT/LT Type:
200VF5A - 4 / 2 kW.
MT Type: 400VF8 - 7,5 kW.
MT/LT Type: 400VF8A - 8 / 4 kW.
3,83 SEPR cooling.
1,92 SEPR freezing.
2,45 SEPR cooling.
1,56 SEPR freezing.
* SEPR values has been tested at 3-part laboratory.
* Model 400VF8A.
OCU-CR200VF5A(SL) 1).
OCU-CR400VF8(SL) / OCU-CR400VF8A(SL) 2).
Cooling capacity (kW)
Cooling capacity (kW)
5,0
10,0
4,0
8,0
3,0
6,0
2,0
4,0
1,0
2,0
OCU-CR400VF8
OCU-CR400VF8A
0
–50
–45
–40
–35
–30
–25
–20
–15
–10
–5
0
0
–50
–45
–40
–35
–30
–25
–20
–15
–10
–5
0
–15
–10
–5
0
Evaporation temperature (ºC)
Evaporation temperature (ºC)
MT Type: 1000VF8 - 15 kW.
MT/LT Type: 1000VF8A - 16 / 8 kW.
NEW MT/LT Type:
2000VF8A - 29 / 15 kW.
2,86 SEPR cooling.
1,49 SEPR freezing.
3,10 SEPR cooling.
1,64 SEPR freezing.
* Model 1000VF8A.
OCU-CR1000VF8(SL) / OCU-CR1000VF8A(SL) 2).
OCU-CR2000VF8A(SL) 1).
Cooling capacity (kW)
Cooling capacity (kW)
20,0
35,0
30,0
15,0
25,0
OCU-CR1000VF8
OCU-CR1000VF8A
20,0
10,0
15,0
10,0
5,0
5,0
0
–50
–45
–40
–35
–30
–25
–20
–15
–10
–5
0
0
–50
–45
–40
–35
Evaporation temperature (ºC)
–30
–25
–20
Evaporation temperature (ºC)
1) Ambient temperature: 32 °C, 230 V, refrigerant: R744, suction gas temperature: 18 °C. 2) Ambient temperature: 32 °C, 400 V, refrigerant: R744, suction gas temperature:18 °C.
1
Superior efficiency with reliable quality
· Panasonic has combined the 2-stage compressor with the
split cycle for increased efficiency
· High seasonal performance. SEPR: Maximum 3,83 in
cooling, 1,92 in freezing 1)
· High COP at high ambient temperature
1) 200VF5A.
2
Heat recovery port 1) as renewable energy
· Maximum 16,7 kW 2) of heating for free
· Optional possibility to get subsidy (depending on location)
· Easy connection process
3
Flexible installation
· Set-points at medium or low temperature
available depending on applications
· Compact unit
· Silent operation
· Long piping length: Maximum 100 m 2)
· High external static pressure
· Transfer pressure control for stable
electric expansion valve control in
showcases 2)
2) For models 1000VF8A and 2000VF8A.
1) For models 1000VF8A and 2000VF8A. 2) For model 1000VF8A.