UK IRE REFRIGERATION GEN 25 - Flipbook - Page 39
iCOOL
REFRIGERATION INDEX
REFRIGERATION
iCOOL SCU Series · R448A / R449A / R134a / R513A
Specifications and capacity tables.
New
2025
Model
SCU-KSC160M08
SCU-KSC190M08
SCU-KSC090L08
Compressor
Tandem compressor
Tandem compressor
Single compressor
Compatible refrigerants
R448A, R449A, R134a,
R513A
R448A, R449A, R134a,
R513A
R448A, R449A
PED category
II
II
II
MT (16,0)
MT (19,0)
LT (9,0)
SEPR cooling at ET -10 °C AT 32 °C
3,14
3,19
—
SEPR freezing at ET -35 °C AT 32 °C
—
—
—
Application and nominal cooling capacity
MT/LT (kW)
Annual electricity consumption at ET -10 °C AT 32 °C
kWh/a
31 411
35 312
—
Annual electricity consumption at ET -35 °C AT 32 °C
kWh/a
—
—
—
Nominal operating current at ET -10 °C MT / -30 °C LT AT 32 °C and
230 - 400 V 50 Hz
A
23,6
28,7
23,0
Maximum operating current (in the most loaded phase at 230 - 400 V 50 Hz)
A
30,5
34,9
32,5
Maximum power consumption
kW
14,6
17,7
14,1
mm
1 327 x 1 558 x 745
1 327 x 1 558 x 745
1 327 x 1 558 x 745
Dimensions
WxHxD
Weight
kg
342
344
325
Sound level at 10 m
dB(A)
55,0
55,0
55,0
Fans x diameter
mm
1x560
1x560
1x560
Air flow
m³/h
9 000
9 000
9 000
Fan static pressure
Pa
120
80
120
Fan power supply
V / ph / Hz
200 - 277 / 1 / 50
200 - 277 / 1 / 50
200 - 277 / 1 / 50
Fan power consumption
W
1050
1 050
1 050
Nominal fan amperage
A
4,6
4,6
4,6
C-SBS180H00B/
C-SBN303H8G
C-SBS180H00B/
C-SBN453H8G
ACC144NA03
Condenser
Model
Compressor
Volumetric flow
m³ / h
5,8 - 17,4 / 11,6
5,8 - 17,4 / 14,7
10,0 - 37,6
Rotation range
rps
32 - 90
32 - 90
25 - 72
Full load amperage
A
14,7 / 8,0
15,2 / 11,9
22,9
Peak current limit / Locked rotor amperage
A
34 / 48
34 / 66
46 / —
FV32S (PVE)
Current
Oil type
FV68S (PVE)
FV68S (PVE)
W
2x70
2x70
90
dm³
2,0 + 1,7 + 2x0,4
2,0 + 1,7 + 2x0,4
2,5 + 0,4
Suction
Inch
1 1/8
1 1/8
1 1/8
Liquid
Inch
5/8
5/8
5/8
dm³
15
15
15
Voltage
V / Hz
3x400 / 50 PE+N (TN-S)
3x400 / 50 PE+N (TN-S)
3x400 / 50 PE+N (TN-S)
Recommended minimum cable cross-section
mm²
5x6,0
5x10,0
5x10,0
C32
C40
C40
m
50
50
40
Evaporator above
m
12
12
12
Evaporator below
m
12
12
12
Crankcase heater power consumption
Oil charge
Connections
Liquid receiver
CU power
supply
Recommended minimum protection
Maximum recommended pipe distance
Maximum height distance
Which pipes needs to be insulated
Suction
Suction
Suction
Recommended insulation thickness
Suction / liquid / both
mm
13
13
19
Maximum quantity of evaporators connected
Qty.
10
10
5
Evaporation temperature
Min ~ Max
°C
-15 ~ 10
-15 ~ 10
-35 ~ -10
Ambient temperature
Min ~ Max
°C
-20 ~ 43
-20 ~ 43
-20 ~ 43
Accessories for iCOOL SCU Series.
Compressor oil FV68S 2 L.
Compressor oil FV32S 2 L.
CZ-HFC-FV68SL2
CZ-HFC-FV32SL2
43 °C
HIGH EFFICIENCY
COMPRESSOR
SUPER QUIET
AMBIENT
TEMPERATURE
AUTOMATIC FAN
CUSTOMIZATION
OPTIONS
BMS
CONNECTIVITY
37