UK IRE REFRIGERATION GEN 25 - Flipbook - Page 44
iCOOL
GENERAL INDEX
iCOOL LCU Series (remote compressor base) · R448A / R449A / R134a / R513A
Specifications and capacity tables.
New
2025
Model
LCU-KRC045M08
LCU-KRC070M08
LCU-KSC100M08
LCU-KSC160M08
LCU-KSC190M08
Compressor
Single
compressor
Single
compressor
Single
compressor
Tandem
compressor
Tandem
compressor
Compatible refrigerants
R448A, R449A,
R134a, R513A
R448A, R449A,
R134a, R513A
R448A, R449A,
R134a, R513A
R448A, R449A,
R134a, R513A
R448A, R449A,
R134a, R513A
PED category
I
II
II
II
II
MT (5,1)
MT (7,2)
MT (10,0)
MT (16,3)
MT (19,6)
A
4,9
7,5
12,1
19,5
24,5
Maximum operating current (in the most loaded phase at 400 V
50 Hz)
A
7,5
11,4
17,9
25,9
30,3
Maximum power consumption
kW
3,5
5,4
8,4
13,6
16,7
mm
1 000 x 705 x 530
1 000 x 772 x 507
1 200 x 775 x 561
1 300 x 874 x 662
1 300 x 874 x 662
Application and nominal cooling capacity
MT/LT (kW)
Nominal operating current at ET -10 °C MT / -30 °C LT AT 32 °C
and 400 V 50 Hz
Dimensions
WxHxD
Weight
kg
85
89
124
209
211
Sound level at 10 m
dB(A)
39,0
42,0
54,0
54,0
54,0
C-7RVN113L0A
C-7RZ320L4ABL
C-SBS180H00B
C-SBS180H00B/
C-SBN303H8G
C-SBS180H00B/
C-SBN453H8G
5,8 - 17,4 / 14,7
Model
Volumetric flow
m³/h
1,25 - 7,5
1,7 - 10,4
5,8 - 17,4
5,8 - 17,4 / 11,6
Rotation range
rps
15-90
15-90
32-90
32-90
32-90
A
5,8
8,7
14,7
14,7 / 8,0
15,2 / 11,9
11,2 / —
15 / —
34 / —
34 / 48
34 / 66
FV68S (PVE)
Compressor
Full load amperage
Current
Peak current limit / Locked rotor
A
amperage
Oil type
Crankcase heater power consumption
Oil charge
FV68S (PVE)
FV68S (PVE)
FV68S (PVE)
35
40
70
2x70
2x70
dm³
0,7 + 0,4
0,7 + 0,4
2,0 + 0,4
2,0 + 1,7 + 2x0,4
2,0 + 1,7 + 2x0,4
Suction
Inch
5/8
3/4
7/8
1 1/8
1 1/8
Liquid
Inch
3/8
3/8
1/2
5/8
5/8
dm³
3,9
7,1
10,0
14
14
Voltage
V / Hz
3x400 / 50 PE+N
(TN-S)
3x400 / 50 PE+N
(TN-S)
3x400 / 50 PE+N
(TN-S)
3x400 / 50 PE+N
(TN-S)
3x400 / 50 PE+N
(TN-S)
Recommended minimum cable cross-section
mm²
5x2,5
5x2,5
5x4,0
5x6,0
5x10,0
C16
C16
C25
C32
C40
m
40
40
40
50
50
Evaporator above
m
12
12
12
12
12
Evaporator below
m
12
12
12
12
12
Suction
Suction
Suction
Suction
Suction
13
Connections
Liquid receiver
CU power
supply
FV68S (PVE)
W
Recommended minimum protection
Maximum recommended pipe distance
Maximum height distance
Which pipes needs to be insulated
Recommended insulation thickness
mm
13
13
13
13
Maximum quantity of evaporators connected
Qty.
5
5
7
10
10
Evaporation temperature
Min ~ Max
°C
-15 ~ 5
-15 ~ 5
-15 ~ 10
-15 ~ 10
-15 ~ 10
Ambient temperature
Min ~ Max
°C
-20 ~ 43
-20 ~ 43
-20 ~ 43
-20 ~ 43
-20 ~ 43