UK VENTILATION GEN 26 - Flipbook - Page 12
GENERAL
R410
AHU connection kit MAH4M for ECOi 2-Pipe · R410A
· Space‑saving compact casing
· Direct Modbus communication without the need for an
additional interface
· Accurate control with a pressure transducer
· PAW‑P+100MAH4M (H x W x D): 300 x 400 x 150 mm, 11 kg
Built-in controller.
AHU kit PAW-P+100MAH4M
AHU connection kit
Outdoor unit
4 HP
5 HP
6 HP
8 HP LE1
8 HP ME2
10 HP LE1
116EEVPACK
116EEVPACK
116EEVPACK
133EEVPACK
133EEVPACK
133EEVPACK
U-4LE2E5(8)
U-5LE2E5(8)
U-6LE2E5(8)
U-8LE1E8
U-8ME2E8
U-10LE1E8
Nominal cooling capacity
kW
12,0
14,0
16,0
22,4
22,4
28,0
Nominal heating capacity
kW
12,5
16,0
17,0
25,0
25,0
31,5
Minimum cooling continuous 1)
kW
4,3
4,3
4,3
7,0
7,0
7,0
Minimum heating continuous 2)
kW
5,0
5,0
5,0
8,1
8,1
8,1
m³/h
1 100
1 100
1 100
1 700
1 700
2 000
8 600
Air flow volume
Min
Max
m³/h
4 000
5 000
5 000
8 000
10 000
AHU DX coil heat
exchanger volume
Min
dm³
1,5
1,5
1,5
2,0
2,0
2,0
Max
dm³
5,5
6,3
7,0
7,0
10,0
7,0
Piping length
Min / Max
m
10 / 100
10 / 100
10 / 100
10 / 100
10 / 100
10 / 100
Maximum branch pipe length
m
12
12
12
12
12
12
Maximum pipe length difference after
1st joint
m
10
10
10
10
10
10
Maximum elevation difference (in / out) m
10
10
10
10
10
10
Piping connections EEV
8
8
8
10
10
10
Piping diameter
branch pipe
On coil temperature
Outdoor temperature
mm
Liquid
Inch (mm)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
3/8 (9,52)
Gas
Inch (mm)
5/8 (15,88)
5/8 (15,88)
5/8 (15,88)
3/4 (19,05)
3/4 (19,05)
7/8 (22,22)
°C DB
12 / 32
12 / 32
12 / 32
12 / 32
12 / 32
12 / 32
°C WB
8 / 25
8 / 25
8 / 25
8 / 25
8 / 25
8 / 25
Heat Min ~ Max °C DB
0 / 32 3)
0 / 32 3)
0 / 32 3)
0 / 32 3)
0 / 32 3)
0 / 32 3)
Cool Min ~ Max
°C DB
‑10 / 46
‑10 / 46
‑10 / 46
‑10 / 46
‑10 / 46
‑10 / 46
Heat Min ~ Max °C WB
Cool Min ~ Max
‑20 / 18
‑20 / 18
‑20 / 18
‑20 / 18
‑25 / 18
‑20 / 18
AHU kit PAW-P+100MAH4M
10 HP ME2
12 HP
14 HP
16 HP
18 HP
20 HP
AHU connection kit
133EEVPACK
133EEVPACK
145EEVPACK
145EEVPACK
145EEVPACK
156EEVPACK
Outdoor unit
U-10ME2E8
U-12ME2E8
U-14ME2E8
U-16ME2E8
U-18ME2E8
2×U-10ME2E8
Nominal cooling capacity
kW
28,0
33,5
40,0
45,0
50,0
56,0
Nominal heating capacity
kW
31,5
37,5
45,0
50,0
56,0
63,0
Minimum cooling continuous 1)
kW
7,0
7,0
10,4
10,4
10,4
15,3
Minimum heating continuous 2)
kW
8,1
8,1
12,0
12,0
12,0
17,5
Min
m³/h
2 000
2 000
3 500
3 500
5 000
5 000
20 000
Air flow volume
Max
m³/h
10 000
10 000
12 000
12 000
20 000
AHU DX coil heat
exchanger volume
Min
dm³
2,0
3,0
3,0
4,0
4,0
4,0
Max
dm³
10,0
17,0
17,0
17,0
19,0
19,0
Piping length
Min / Max
m
10 / 100
10 / 100
10 / 100
10 / 100
10 / 100
10 / 100
Maximum branch pipe length
m
12
12
12
12
12
12
Maximum pipe length difference after
1st joint
m
10
10
10
10
10
10
Maximum elevation difference (in / out) m
10
10
10
10
10
10
Piping connections EEV
10
10
10
10
10
16
Piping diameter
branch pipe
On coil temperature
Outdoor temperature
mm
Liquid
Inch (mm)
3/8 (9,52)
1/2 (12,70)
1/2 (12,70)
1/2 (12,70)
5/8 (15,88)
5/8 (15,88)
Gas
Inch (mm)
7/8 (22,22)
1 1/8 (28,58)
1 1/8 (28,58)
1 1/8 (28,58)
1 1/8 (28,58)
1 1/8 (28,58)
°C DB
12 / 32
12 / 32
12 / 32
12 / 32
12 / 32
12 / 32
°C WB
8 / 25
8 / 25
8 / 25
8 / 25
8 / 25
8 / 25
Heat Min ~ Max °C DB
0 / 32 3)
0 / 32 3)
0 / 32 3)
0 / 32 3)
0 / 32 3)
0 / 32 3)
Cool Min ~ Max
°C DB
‑10 / 46
‑10 / 46
‑10 / 46
‑10 / 46
‑10 / 46
‑10 / 46
Heat Min ~ Max °C WB
Cool Min ~ Max
‑25 / 18
‑25 / 18
‑25 / 18
‑25 / 18
‑25 / 18
‑25 / 18
1) At rated condition with 35 °C DB outdoor and 27 °C DB / 19 °C WB on coil. 2) At rated condition with 7 °C DB / 6 °C WB outdoor and 20°C DB on coil. 3) In case of on coil temperature of 5 °C or below and of
31 °C and above air flow would be restricted.
12